Skip to the guide

Industrial networking

Belden 9841 One Pair or 9842 Two Pair

Use 9841 for one 24 AWG pair at 0.232 in. Use 9842 for two 24 AWG pairs at 0.340 in. Both sheets list 120 Ohm and CM.

Rust Belt Industrials · October 26, 2026 · Updated November 5, 2026 · 6 min read

On this page

Use Belden 9841 when the RS-485 cable is one pair. As of October 26, 2026, that sheet lists one 24 AWG (7x32) tinned-copper pair, a nominal jacket diameter of 0.232 in (5.89 mm), 120 Ohm, and 2.1 A per conductor at 25°C with a 10°C temperature rise in the current cell. Use Belden 9842 when the cable is two pairs. As of the same day, that sheet lists two 24 AWG (7x32) tinned-copper pairs, a nominal jacket diameter of 0.340 in (8.64 mm), 120 Ohm, and 2.1 A per conductor at 25°C. The 9842 current cell does not add the 10°C rise note. Belden's RS-485 category, opened the same day, puts both numbers on the light-industrial block: 9841 at 1 pair and 9842 at 2 pair, 24 AWG, PVC. A 150 Ohm PROFIBUS cable is a different match, on the 9841 and 3079A page.

The light-industrial block names the pair count

As of October 26, 2026, the category page's light-industrial table lists SF/UTP, 24 AWG, and a PVC jacket, then 9841 at 1 pair, 9842 at 2 pair, 9843 at 3 pair, and 9844 at 4 pair. The 9841 row prints CMG in the rating cell, with the part number in the technical-data column. The 9842 row prints 2 pair and the part number. The 9841 sheet and the 9842 sheet each print 300 V (CM) and NEC Article 800, CM. Copy CM from the sheet you named. The 3-pair and 4-pair sheets are on the 9843 and 9844 page. The high-flex 3-pair sheet, 53 Ohm as of October 27, 2026, is on the 9843 and 7202A page.

The same light-industrial table lists an LSNH row. The 1-pair cell is 9841ZH. The 2-pair cell is a download. That file was not opened, so this page does not give it a diameter or a listing. Both sheets print a non-plenum number of 9841ZH, as of October 26, 2026. That string matches the 1-pair LSNH cell. It does not, by itself, name a 2-pair LSNH construction. Plenum numbers on the 9841 sheet are 82841 and 89841. Plenum numbers on the 9842 sheet are 82842 and 89842. Jacket and temperature for the one-pair plenum pair are on the 82841 and 89841 page. Jacket and temperature for the two-pair plenum pair are on the 82842 and 89842 page.

Same gauge, one pair or two

As of October 26, 2026, both sheets list 24 AWG, 7x32, tinned copper, polyethylene insulation, a 100% bi-laminate tape, a 24 AWG (7x32) tinned-copper drain, a 90% tinned-copper braid, and a PVC jacket. 9841 insulation thickness is 0.023 in (0.58 mm). 9842 insulation thickness is 0.022 in (0.56 mm). Both list a nominal insulation diameter of 0.068 in (1.7 mm). 9841 colors are white/blue stripe and blue/white stripe. 9842 adds a second pair, white/orange stripe and orange/white stripe. Jacket thickness is 0.035 in (0.89 mm) on both. Jacket OD tolerance is +/- 0.020 in on 9841 and +/- 0.025 in on 9842.

Pair-count rows from the Belden sheets opened October 26, 2026.
Item98419842
Pairs12
Gauge24 AWG, 7x32, tinned copper24 AWG, 7x32, tinned copper
Nominal jacket OD0.232 in (5.89 mm)0.340 in (8.64 mm)
Jacket OD tolerance+/- 0.020 in+/- 0.025 in
Impedance120 Ohm120 Ohm
Current cell2.1 A per conductor at 25°C, 10°C rise2.1 A per conductor at 25°C
Maximum pull tension72.3 lbs (32.8 kg)87 lbs (39 kg)
UL voltage300 V (CM), 30 V (UL AWM 2919)300 V (CM), 30 V (UL AWM 2919)

120 Ohm on both, with a different delay and shield DCR

As of October 26, 2026, both sheets list conductor DCR of 24 Ohm/1000ft (79 Ohm/km), capacitance of 12.8 pF/ft (42.0 pF/m) conductor to conductor and 23 pF/ft (75 pF/m) conductor to other, velocity of 66%, and nominal insertion loss of 0.6 dB/100ft at 1 MHz. Delay is 1.6 ns/ft on 9841 and 1.54 ns/ft on 9842. Outer-shield DCR is 3.4 Ohm/1000ft (11 Ohm/km) on 9841 and 2.2 Ohm/1000ft (7.2 Ohm/km) on 9842. The voltage cell on both sheets is 300 V (CM) and 30 V (UL AWM 2919). AWM compliance on both is AWM 2919. The other-standard cell on both is DMX-512.

Indoor CM, with a larger bend on the two-pair cable

As of October 26, 2026, both sheets list UL temperature 80°C, operating temperature -30°C to +80°C, environmental suitability indoor, flammability UL 1685 UL Loading and IEC 60332-1-2, and CPR Euroclass Eca plus UKCA Class Eca. NEC and CEC compliance are Article 800, CM. Minimum bend radius, stationary and installation, is 2.5 in (64 mm) on 9841 and 3.5 in (89 mm) on 9842. Maximum pull tension is 72.3 lbs (32.8 kg) on 9841 and 87 lbs (39 kg) on 9842. Bulk weight is 36 lbs/1000ft (54 kg/km) on 9841 and 49 lbs/1000ft (73 kg/km) on 9842. Page revision is 0.725, dated 02-25-2026, on 9841, and 0.736, dated 02-25-2026, on 9842.

The applications sentence on both sheets, as of October 26, 2026, names RS-485, point of sale, computer communications, low-voltage analog signals, low-voltage digital control, line-level audio, panel wiring, and serial communication under the RS-485 standard. A 22 AWG cable at the same 120 Ohm, with PLTC and an outdoor line, is 3105A, on the 3105A and 9841 page. Two pairs at 22 AWG are 3107A, on the 3105A and 3107A page.

What to copy onto the cable line

  • Part: 9841 or 9842, from the sheet opened October 26, 2026.
  • Pairs: one, colors white/blue and blue/white, or two, adding white/orange and orange/white.
  • Nominal diameter: 0.232 in (5.89 mm), or 0.340 in (8.64 mm).
  • Impedance: 120 Ohm on the part you named.
  • Current: 2.1 A per conductor at 25°C, and the 10°C rise note only if the part is 9841.
  • Listing from the sheet: 300 V (CM) and 30 V (UL AWM 2919). Leave the category CMG cell off.

9841 or 9842 note

Name the pair count and copy the diameter from that sheet.

This prepares a request. It does not send one.

Questions these sheets answer

Does 120 Ohm pick the pair count?

Both impedance cells are 120 Ohm, as of October 26, 2026. The pair count, the jacket diameter, and the pull tension pick 9841 or 9842. A request that says only 120 Ohm and 24 AWG has not chosen the pair count.

Where is the 10°C rise?

The 9841 current cell prints 2.1 A per conductor at 25°C and a 10°C temperature rise, as of October 26, 2026. The 9842 current cell prints 2.1 A per conductor at 25°C and does not print that rise note. Copy the cell that belongs to the part.

Which listing is CMG?

The 9841 row prints CMG in the rating cell, as of October 26, 2026. The 9842 row on that table prints the pair count and the part number. The 9841 sheet and the 9842 sheet print CM. The request uses the sheet for the part it names.

Sources

Pair count, diameter, impedance, current, voltage, temperature, and the non-plenum string are from the Belden 9841 and 9842 technical data sheets. The light-industrial pair rows and the CMG rating cell are from the Belden RS-485 category page. All three were opened October 26, 2026. 9843 and 9844 were opened October 27, 2026 for the page linked above. The LSNH download was not opened. The four plenum sheets were opened November 5, 2026 for the pages linked above.