Belden 3105A One Pair or 3107A Two Pair
Use 3105A for one 22 AWG pair at 6 A and 0.294 in. Use 3107A for two 22 AWG pairs at 4.8 A and 0.350 in.
On this page
Use Belden 3105A when the 22 AWG RS-485 cable is one pair. As of October 26, 2026, that sheet lists one 22 AWG (7x30) tinned-copper pair, a nominal jacket diameter of 0.294 in (7.47 mm), 120 Ohm, and 6 A per conductor at 30°C. Use Belden 3107A when the cable is two pairs. As of the same day, that sheet lists two 22 AWG (7x30) tinned-copper pairs, a nominal jacket diameter of 0.350 in (8.89 mm), 120 Ohm, and 4.8 A per conductor at 30°C. The category page prints 1 pair for 3105A and 2 pair for 3107A. A two-pair cable at 24 AWG and CM is 9842, on the 9841 and 9842 page.
The harsh table separates 1 pair from 2 pair
As of October 26, 2026, the industrial and harsh table lists 3105A at 1 pair, 3106A at 1.5 pair, and 3107A at 2 pair, all SF/UTP and 22 AWG. 3106A is the one-pair-plus-conductor cable, on the 3105A and 3106A page. The 3105A sheet and the 3107A sheet each print 300 V (CM, PLTC). The 3107A title line says CM, PLTC, and oil resistant. Sunlight resistance is on the suitability cell, with indoor, outdoor, and oil resistance. 3108A and 3109A, the 3-pair and 4-pair sheets, are on the 3108A and 3109A page. The CPE direct-burial jacket at three pairs is on the 3108A and 3108DB page.
One color pair, or two
As of October 26, 2026, 3105A insulation is foam polyethylene, 0.029 in (0.74 mm), nominal insulation diameter 0.087 in (2.2 mm), white/blue stripe and blue/white stripe, notes HDPE. 3107A insulation is foam polyethylene, 0.025 in (0.64 mm), nominal insulation diameter 0.079 in (2.0 mm), with two color pairs: white/blue stripe and blue/white stripe, and white/orange stripe and orange/white stripe, notes HDPE. Both shields are a 100% bi-laminate tape with a 22 AWG (7x30) tinned-copper drain, plus a 65% tinned-copper braid. The 3105A jacket is PVC, 0.047 in (1.2 mm), nominal diameter 0.294 in (7.47 mm), tolerance +/- 0.006 in. The 3107A jacket is PVC, 0.053 in (1.3 mm), nominal diameter 0.350 in (8.89 mm). The 3107A sheet does not print a jacket OD tolerance.
| Item | 3105A | 3107A |
|---|---|---|
| Category pair column | 1 | 2 |
| Pairs on the sheet | 1 | 2 |
| Nominal jacket OD | 0.294 in (7.47 mm) | 0.350 in (8.89 mm) |
| Jacket thickness | 0.047 in (1.2 mm) | 0.053 in (1.3 mm) |
| Impedance | 120 Ohm | 120 Ohm |
| Current | 6 A per conductor at 30°C | 4.8 A per conductor at 30°C |
| Outer-shield DCR | 4.685 Ohm/1000ft (15.37 Ohm/km) | 3.663 Ohm/1000ft (12.02 Ohm/km) |
| Maximum pull tension | 53.34 lbs (24.19 kg) | 80 lbs (36 kg) |
The current cell changes with the pair count
As of October 26, 2026, both sheets list conductor DCR of 18.2 Ohm/1000ft, with no kilometer figure in that cell, capacitance of 11 pF/ft (36 pF/m) conductor to conductor and 20.9 pF/ft (68.6 pF/m) conductor to other, impedance of 120 Ohm, velocity of 78%, and insertion loss of 0.5 dB/100ft at 1 MHz. Neither sheet prints inductance. Current is 6 A per conductor at 30°C on 3105A and 4.8 A per conductor at 30°C on 3107A. Outer-shield DCR is 4.685 Ohm/1000ft (15.37 Ohm/km) on 3105A and 3.663 Ohm/1000ft (12.02 Ohm/km) on 3107A. Both voltage cells are 300 V (CM, PLTC). 3107A's other-standard cell says DMX-512. 3105A's standards block does not.
Oil and sunlight on both suitability lines
As of October 26, 2026, both sheets list UL temperature 60°C, operating temperature -20°C to +60°C, and suitability indoor, outdoor, sunlight resistance, and oil resistance. Flammability is UL 1685 UL Loading and IEC 60332-1-2. NEC compliance is Article 725, Article 800, CM, PLTC. CEC compliance is CM. CPR is Euroclass Eca and UKCA Class Eca. Minimum bend radius is 3.372 in (85.65 mm) on 3105A and 4.2 in (110 mm) on 3107A. Maximum pull tension is 53.34 lbs (24.19 kg) on 3105A and 80 lbs (36 kg) on 3107A. Bulk weight is 43 lbs/1000ft on 3105A and 58 lbs/1000ft on 3107A. Neither weight cell prints a kilogram. Both notes say oil resistance passes Oil Res II per UL 1277, Table 10.17. The CPE note names YR44345 on 3105A and YR46792 on 3107A. Those pages were not opened. Page revision is 0.598, dated 02-20-2026, on both sheets.
A one-pair 24 AWG cable at 120 Ohm, listed CM and indoor, is 9841, as of October 26, 2026, on the 3105A and 9841 page. The category's 2-pair light-industrial cell is 9842, at 2.1 A and 24 AWG. 3107A is 22 AWG at 4.8 A.
What to copy onto the cable line
- Part: 3105A or 3107A, from the sheet opened October 26, 2026.
- Pairs: one, or two, with the color list from that sheet.
- Nominal diameter: 0.294 in (7.47 mm), or 0.350 in (8.89 mm).
- Current: 6 A per conductor at 30°C, or 4.8 A per conductor at 30°C.
- Impedance: 120 Ohm on the part you named.
- Listing: 300 V (CM, PLTC), and the sunlight line from the suitability cell.
Questions these sheets answer
Does two pairs keep the 6 A cell?
3105A prints 6 A per conductor at 30°C, as of October 26, 2026. 3107A prints 4.8 A per conductor at 30°C. The impedance cell stays 120 Ohm. The current cell does not.
Does the 3107A title omit sunlight?
The 3107A title says CM, PLTC, and oil resistant, as of October 26, 2026. The suitability cell lists sunlight resistance, along with indoor, outdoor, and oil resistance. Copy the suitability cell when the route needs that line.
Is 9842 the two-pair version of 3107A?
9842 is two 24 AWG pairs, CM, and 2.1 A at 25°C. 3107A is two 22 AWG pairs, CM and PLTC, and 4.8 A at 30°C. Both were opened October 26, 2026. The category puts them in different tables.
Sources
Pair count, diameter, current, shield DCR, and the title line are from the Belden 3105A and 3107A technical data sheets. The 1 pair and 2 pair labels are from the Belden RS-485 category page. All three were opened October 26, 2026. 3108A and 3109A were opened October 27, 2026 for the page linked above. YR44345 and YR46792 were not opened.