Skip to the guide

Industrial networking

Belden 9842 CM or 82842 CMP for Two-Pair RS-485

Use 9842 for two pairs at 0.340 in, CM, and 2.1 A. Use 82842 for two pairs at 0.273 in, CMP, and 3.2 A. Both list 120 Ohm.

Rust Belt Industrials · October 29, 2026 · Updated November 5, 2026 · 6 min read

On this page

Use Belden 9842 when the two-pair RS-485 cable is the non-plenum CM number. As of October 29, 2026, that sheet lists a PVC jacket of 0.340 in (8.64 mm), polyethylene insulation, 2.1 A per conductor at 25°C, and an operating range of -30°C to +80°C. Use Belden 82842 when the two-pair cable is the plenum CMP number. As of the same day, that sheet lists a PVC jacket of 0.273 in (6.93 mm), FEP foam insulation, 3.2 A per conductor at 25°C, and an operating range of 0°C to +75°C. Both sheets list two 24 AWG pairs and 120 Ohm. 9842's plenum-number cell names 82842 and 89842. 82842's non-plenum-number cell names 9842. The one-pair plenum number is 82841, on the 9841 and 82841 page.

82842 names 9842, and 9842's non-plenum cell still prints 9841ZH

As of October 29, 2026, 9842 prints Plenum Number 82842, 89842, and Non-Plenum Number 9841ZH. 82842 prints Non-Plenum Number 9842. A request for 82842 copies 9842 from 82842's own cell. A request for 9842 copies 82842 from 9842's plenum cell, and it also copies the 9841ZH string that 9842 prints in the non-plenum cell. The 9841ZH sheet was not opened. The April 2022 line card lists 9842 as two pair, 24 AWG, PVC, CMG, light industrial, and 82842 as two pair, 24 AWG, PVC, CMP, light industrial. The 9842 technical data sheet prints CM, not CMG. Copy CM from that sheet. The line card's CMG cell stays a line-card reading. 89842 is the line card's FEP row at CMP. The 89842 sheet, opened November 5, 2026, lists that FEP jacket at 0.345 in (8.76 mm) and 4 A per conductor at 25°C. 82842 remains 0.273 in and 3.2 A. The jacket choice is on the 82842 and 89842 page.

Two 24 AWG pairs, polyethylene at 0.340 in or FEP foam at 0.273 in

As of October 29, 2026, both sheets list two pairs of 24 AWG 7x32 tinned copper, a 100% bi-laminate tape with a 24 AWG (7x32) tinned-copper drain, and a 90% tinned-copper braid. Pair colors on both are white/blue stripe and blue/white stripe, plus white/orange stripe and orange/white stripe. 9842's insulation is polyethylene, 0.022 in (0.56 mm) thick, nominal insulation diameter 0.068 in (1.7 mm). The jacket is PVC, 0.035 in (0.89 mm) thick, nominal diameter 0.340 in (8.64 mm), and the jacket OD note is plus or minus 0.025 in. 82842's insulation is FEP foam, 0.019 in (0.48 mm) thick, nominal insulation diameter 0.062 in (1.6 mm). The jacket is PVC, 0.015 in (0.38 mm) thick, nominal diameter 0.273 in (6.93 mm). That sheet does not print a jacket OD tolerance. Suitable applications on both name RS-485 and the same serial-communication list printed on the one-pair sheets.

9842 and 82842 rows from the technical data sheets opened October 29, 2026.
Item984282842
Listing on the sheetCMCMP
JacketPVC, 0.340 inPVC, 0.273 in
InsulationPolyethyleneFEP foam
Impedance120 Ohm120 Ohm
Current2.1 A at 25°C3.2 A at 25°C
Operating range-30°C to +80°C0°C to +75°C
UL temperature80°C75°C
Cross-referencePlenum number 82842, 89842Non-plenum number 9842

120 Ohm on both, and the 2.1 A cell has no rise note

As of October 29, 2026, both impedance cells print 120 Ohm. 9842 lists nominal conductor DCR of 24 Ohm/1000ft (79 Ohm/km), capacitance of 12.8 pF/ft (42.0 pF/m) and 23 pF/ft (75 pF/m), delay of 1.54 ns/ft, and velocity of 66%. Outer-shield DCR is 2.2 Ohm/1000ft (7.2 Ohm/km). The current cell is 2.1 A per conductor at 25°C. It does not print the 10°C rise note that the 9841 sheet prints. 82842 lists nominal conductor DCR of 24 Ohm/1000ft, with no kilometer figure in that cell, capacitance of 12 pF/ft (39 pF/m) and 22 pF/ft (72 pF/m), and velocity of 76%. The 82842 row does not print a delay. Outer-shield DCR is 2.4 Ohm/1000ft (7.9 Ohm/km). The current cell is 3.2 A per conductor at 25°C. Nominal insertion loss at 1 MHz is 0.6 dB/100ft on both. Neither table prints a row past 1 MHz.

9842's UL voltage rating, as of October 29, 2026, is 300 V (CM) and 30 V (UL AWM 2919). NEC / UL compliance is Article 800, CM. AWM compliance is AWM 2919. The other-standard cell names DMX-512. Flammability is UL 1685 UL Loading and IEC 60332-1-2. CPR is Euroclass Eca and UKCA Class Eca. 82842's UL voltage rating is 300 V (CMP). NEC / UL and CEC compliance are CMP. That sheet does not print an AWM line or a DMX-512 line. Flammability is NFPA 262, UL 910 (Plenum), FT6, and IEC 60332-1-2. CPR is Euroclass Eca. Environmental suitability on both is indoor. 9842's non-plenum cell prints 9841ZH beside those listing lines. 82842 does not print 9841ZH.

Pull, bend, and the natural two-pair put-ups

As of October 29, 2026, 9842 lists UL temperature 80°C, operating temperature -30°C to +80°C, minimum bend radius 3.5 in (89 mm) for stationary and installation, maximum pull tension 87 lbs (39 kg), and bulk weight 49 lbs/1000ft (73 kg/km). 82842 lists UL temperature 75°C, operating temperature 0°C to +75°C, bend radius 2.75 in (69.9 mm), pull tension 56.7 lbs (25.7 kg), and bulk weight 38 lbs/1000ft. Page revision is 0.736, dated 02-25-2026, on 9842, and 0.544, dated 02-20-2026, on 82842. The 82842 variant table prints 82842 8771000, 82842 877500, and 82842 8775000, all natural. Footnote C is on 8771000 and 877500. The table does not print a length.

What to copy onto the cable line

  • Part: 9842 or 82842, from the sheet opened October 29, 2026.
  • Listing: CM, or CMP.
  • Jacket: PVC at 0.340 in with the 0.025 in tolerance, or PVC at 0.273 in with no tolerance printed.
  • Pairs: two 24 AWG pairs, white/blue and white/orange.
  • Impedance: 120 Ohm.
  • Current: 2.1 A at 25°C, or 3.2 A at 25°C. Neither cell prints a rise note.
  • Temperature: 80°C and -30°C to +80°C, or 75°C and 0°C to +75°C.
  • Cross-reference: plenum numbers 82842 and 89842, and the 9841ZH string on 9842. 82842's non-plenum number is 9842.

9842 or 82842 note

Name the two-pair part and copy the listing, jacket, and current from that sheet.

This prepares a request. It does not send one.

Questions these sheets answer

Does 9842 carry 9841's 10°C rise note?

9842's current cell is 2.1 A per conductor at 25°C, as of October 29, 2026. The cell does not print a rise note. 82842's current cell is 3.2 A at 25°C, also with no rise note.

Does 9841ZH mean 82842?

9842's non-plenum-number cell prints 9841ZH, as of October 29, 2026. 82842's non-plenum-number cell prints 9842. The two strings are different cells. 9841ZH was not opened.

Does the two-pair plenum sheet keep -30°C?

9842's operating range is -30°C to +80°C, as of October 29, 2026. 82842's operating range is 0°C to +75°C.

Sources

Pair count, jacket, insulation, impedance, current, temperature, listing, and the cross-reference cells for 9842 and 82842 are from those technical data sheets, opened October 29, 2026. The April 2022 line card, opened the same day, is the source for the CMG cell on 9842. The 89842 jacket, 0.345 in, and 4 A are from the 89842 technical data sheet opened November 5, 2026.