Industrial networking
Belden 3105A One Pair or 3106A Plus One Conductor
Use 3105A for one 22 AWG pair at 0.294 in. Use 3106A when the sheet adds one 22 AWG conductor and the diameter is 0.310 in.
On this page
Use Belden 3105A when the harsh-applications row is one pair. As of October 26, 2026, that sheet lists one 22 AWG (7x30) tinned-copper pair, a nominal jacket diameter of 0.294 in (7.47 mm), 120 Ohm, and 6 A per conductor at 30°C. Use Belden 3106A when the cable adds one 22 AWG conductor beside the pair. As of the same day, that sheet lists one 22 AWG (7x30) pair plus one 22 AWG (7x30) tinned-copper conductor, a nominal jacket diameter of 0.310 in (7.87 mm), 120 Ohm on the pair, and 6 A per conductor at 30°C on both the pair and the single conductor. The category page prints 1 pair for 3105A and 1.5 pair for 3106A, both 22 AWG. Two full pairs at this gauge are 3107A, on the 3105A and 3107A page.
1 pair and 1.5 pair are the category labels
As of October 26, 2026, the industrial and harsh table lists 3105A at 1 pair and 3106A at 1.5 pair, both SF/UTP and 22 AWG. The listing on the request comes from the sheet, 300 V (CM, PLTC), on both parts. The 1.5 label is the category's pair column. The sheet's conductor table is the place that 1.5 becomes a pair plus a single conductor. A request names 3106A and then copies both rows from the sheet.
The extra conductor is PVC, and the pair color changes
As of October 26, 2026, the 3105A pair is foam polyethylene, 0.029 in (0.74 mm), nominal insulation diameter 0.087 in (2.2 mm), white/blue stripe and blue/white stripe, notes HDPE. 3106A's pair is foam polyethylene, 0.033 in (0.84 mm), nominal insulation diameter 0.095 in (2.4 mm), white/orange stripe and orange/white stripe, notes HDPE. The single conductor is PVC, 0.017 in (0.43 mm), nominal insulation diameter 0.062 in (1.6 mm), blue/white stripe. Both descriptions say Datalene on the pair. Both shields are a 100% bi-laminate tape with a 22 AWG (7x30) tinned-copper drain, plus a 65% tinned-copper braid. Jacket thickness is 0.047 in (1.2 mm) on both. 3105A prints a jacket OD tolerance of +/- 0.006 in. The 3106A sheet does not print a jacket OD tolerance.
| Item | 3105A | 3106A |
|---|---|---|
| Category pair column | 1 | 1.5 |
| Elements on the sheet | 1 pair | 1 pair and 1 conductor |
| Pair colors | White/blue and blue/white | White/orange and orange/white |
| Single conductor | None on the sheet | 22 AWG, 7x30, PVC, blue/white stripe |
| Nominal jacket OD | 0.294 in (7.47 mm) | 0.310 in (7.87 mm) |
| Pair impedance | 120 Ohm | 120 Ohm |
| Current | 6 A per conductor at 30°C | 6 A per conductor at 30°C, pair and single |
| Maximum pull tension | 53.34 lbs (24.19 kg) | 75.26 lbs (34.14 kg) |
120 Ohm stays on the pair
As of October 26, 2026, both pair rows list conductor DCR of 18.2 Ohm/1000ft, capacitance of 11 pF/ft (36 pF/m) conductor to conductor and 20.9 pF/ft (68.6 pF/m) conductor to other, impedance of 120 Ohm, velocity of 78%, and insertion loss of 0.5 dB/100ft at 1 MHz. 3106A also prints pair inductance of 0.203 µH/ft (0.666 µH/m). 3105A does not print inductance. The 3106A single-conductor row lists DCR of 18.2 Ohm/1000ft (59.7 Ohm/km) and 6 A per conductor at 30°C. It does not print capacitance or impedance. Outer-shield DCR is 4.685 Ohm/1000ft (15.37 Ohm/km) on 3105A and 4.544 Ohm/1000ft (14.91 Ohm/km) on 3106A. Both voltage cells are 300 V (CM, PLTC).
Same temperature line, different bend and weight
As of October 26, 2026, both sheets list UL temperature 60°C, operating temperature -20°C to +60°C, suitability indoor, outdoor, sunlight resistance, and oil resistance, flammability UL 1685 UL Loading and IEC 60332-1-2, and NEC Article 725, Article 800, CM, PLTC. CEC compliance is CM. Minimum bend radius is 3.372 in (85.65 mm) on 3105A and 3.6 in (91 mm) on 3106A, stationary and installation. Maximum pull tension is 53.34 lbs (24.19 kg) on 3105A and 75.26 lbs (34.14 kg) on 3106A. Bulk weight is 43 lbs/1000ft on 3105A and 48 lbs/1000ft on 3106A. Neither weight cell prints a kilogram. Both notes say oil resistance passes Oil Res II per UL 1277, Table 10.17. The CPE note names YR44345 on 3105A and YR46721 on 3106A. Those pages were not opened. Page revision is 0.598 on 3105A and 0.595 on 3106A, both dated 02-20-2026.
A 24 AWG one-pair cable at 120 Ohm, listed CM and indoor, is 9841, on the 3105A and 9841 page. The category also names 3106DB on a CPE direct-burial row at 1.5 pair, as of October 26, 2026. That sheet was not opened.
What to copy onto the cable line
- Part: 3105A or 3106A, from the sheet opened October 26, 2026.
- Elements: one pair, or one pair plus the 22 AWG PVC conductor.
- Category pair column: 1, or 1.5, beside the sheet's element table.
- Nominal diameter: 0.294 in (7.47 mm), or 0.310 in (7.87 mm).
- Pair impedance: 120 Ohm. Leave impedance blank on the single conductor.
- Current: 6 A per conductor at 30°C, and name which element the cell covers on 3106A.
Questions these sheets answer
What does 1.5 pair mean on the sheet?
The category pair column prints 1.5 for 3106A, as of October 26, 2026. The conductor table prints one pair and one conductor, both 22 AWG, 7x30, tinned copper. The pair insulation is foam polyethylene. The single conductor insulation is PVC.
Does the single conductor get 120 Ohm?
120 Ohm is on the pair row, as of October 26, 2026. The single-conductor row prints DCR and current. It does not print impedance. The request keeps 120 Ohm on the pair.
Does 6 A make the cables the same part?
Both current cells are 6 A per conductor at 30°C, as of October 26, 2026. The element table, the pair color, the jacket diameter, and the pull tension still differ. 3105A pull tension is 53.34 lbs. 3106A pull tension is 75.26 lbs.
Sources
Elements, colors, diameter, impedance, current, and the CPE notes are from the Belden 3105A and 3106A technical data sheets. The 1 pair and 1.5 pair labels are from the Belden RS-485 category page. All three were opened October 26, 2026. YR44345, YR46721, and 3106DB were not opened.