Power connections
Busbar Insulation Tape: Scotch 2228 or Raychem HVBT
Use Scotch 2228 at 1.65 mm for a bolted bus connection up to 35 kV. Use Raychem HVBT when one two-thirds overlap is at least 17.5 kV and a second layer is 36 kV.
On this page
Use 3M Scotch 2228 when the cover is a self-fusing rubber mastic pad on a bolted bus connection. As of November 11, 2026, the 3M datasheet, issue 10.12.2018, lists that tape at 1.65 mm for bus bar connections rated up to 35 kV on 3M drawing 2047B-106, classified for normal service up to 90°C and short-term exposure up to 130°C. Use Raychem HVBT when the cover is a heat-shrink tape. As of the same day, the TE product page and datasheet EPP-2660-10/18 say one layer, two-thirds overlapped, provides AC voltage withstand to at least 17.5 kV, and a second layer increases that to 36 kV. HVBT's continuous operating temperature is up to 90°C, and the tape is flexible down to -40°C. A removable boot on the joint is the boot page. Tubing on the bar run is the heat-shrink page.
The joint pad and the heat-shrink wrap use different voltage lines
Scotch 2228 and HVBT can both cover a busbar connection, and the sheets name different builds. The 2228 applications list, opened November 11, 2026, separates primary insulation for cable and wire connections rated up to 1000 volts from primary electrical insulation for bus bar connections rated up to 35 kV. Motor-lead insulation and vibration padding on that sheet also stop at 1000 volts. The 35 kV line is the bus bar connection, and it cites 3M drawing 2047B-106. HVBT's product page, opened the same day, prints a voltage class up to 36 kV. The withstand sentence is the layer count: one two-thirds-overlapped layer for at least 17.5 kV, and a second layer for 36 kV.
| Tape | Voltage line | Temperature | Build |
|---|---|---|---|
| Scotch 2228 | Bus bar connections up to 35 kV, drawing 2047B-106. Cable and motor leads up to 1000 V. | 90°C normal service. Short-term exposure up to 130°C. Apply at 0°C to 38°C. | 1.65 mm. Half-lapped layers, stretched to 3/4 of the original width. |
| Raychem HVBT | One layer, two-thirds overlapped, at least 17.5 kV. A second layer, 36 kV. Voltage class up to 36 kV. | Continuous operating temperature up to 90°C. Flexible down to -40°C. Operating range -40°C to 90°C. | Heat-shrink polyolefin, red. Widths 25 mm, 50 mm, and 100 mm. |
Scotch 2228 is the 1.65 mm mastic for a bolted bus connection
The datasheet opened November 11, 2026 describes Scotch 2228 as ethylene propylene rubber backing with a mastic adhesive. Section 4.1 classifies the tape for normal service temperatures up to 90°C, with allowable short-term exposure up to 130°C, and says the tape is 1.65 mm thick. It is applicable at 0°C to 38°C. The sheet says it is for indoor use and for weather-exposed outdoor use, and that it is compatible with synthetic cable insulation and is not corrosive to aluminum or copper conductors. Installation is half-lapped layers until the build is reached, with the tape stretched to 3/4 of its original width. The sheet then calls for an overwrap of two half-lapped layers of Scotch vinyl electrical tape for mechanical protection.
The typical-properties table on that sheet, measured at 23°C, prints temperature rating 90°C to ASTM D4388, color black, thickness 1.65 mm to ASTM D4325, adhesion 26.2 N/10 mm on steel and 17.5 N/10 mm on PE, tensile strength 1.03 N/mm², elongation 1000%, and dielectric breakdown 19.7 kV/mm dry and 19.7 kV/mm wet. The sheet says those typical values should not be used for specification purposes. The 35 kV busbar line, the 1000 V cable line, the 1.65 mm thickness, and the 90°C and 130°C classification are in the applications list and in section 4.1. Shelf life on the sheet is 5 years from the date of manufacture when stored at 21°C and 40 to 50 percent relative humidity, as of the issue dated 10.12.2018. A water-seal note on the sheet says a 336-hour cycle between 25°C and 90°C water baths showed no significant change in insulation resistance, and it says that result exceeds the UL 486D figures the note names: 6.0 megohms and 2.2 kV for 1 minute. Those two figures are the UL 486D values in the note. They are not a second busbar voltage rating.
HVBT is the heat-shrink wrap at 17.5 kV for one layer and 36 kV for two
The TE product page opened November 11, 2026 describes HVBT as heat-shrink tape with an adhesive coating. Heat shrinks the tape, the adhesive melts, and the overlapping layers form a lap-to-lap seal. The page says the tape adheres to itself and to other insulating materials, and that it does not adhere to metal or porcelain, so it can be removed for maintenance. It names indoor and outdoor use, and it names complex connections where the equipment stays assembled. Key features on the page are a continuous operating temperature up to 90°C and flexibility down to -40°C. The usage block prints an operating temperature range of -40°C to 90°C. Primary material is polyolefin. Primary color is red. Voltage class is up to 36 kV. Product widths are 25 mm, 50 mm, and 100 mm, which the page also prints as 1 in, 2 in, and 4 in.
Datasheet EPP-2660-10/18, opened the same day, repeats the 17.5 kV and 36 kV layer sentence, the 90°C continuous temperature, and the -40°C flexibility line. It says the property block refers to the backing material only. That block prints dielectric strength greater than 130 kV/cm (330 V/mil) at 2.0 mm thickness to ASTM D149, volume resistivity 1 x 10^13 ohm cm minimum to ASTM D257, water absorption 0.2 percent maximum after 24 hours at 23°C to ASTM D570, and no cracking after 4 hours at -40°C to ASTM D2671. Accelerated ageing is 168 hours at 120°C, with tensile strength 10 MPa minimum and ultimate elongation 300 percent minimum. Resistance to transformer oil is 168 hours at 23°C, with the same 10 MPa and 300 percent minimums. The length table on that PDF prints meters of tape per meter of rectangular bar: HVBT-12-A(B20) at 10 m for a 25 mm width, HVBT-14-A(B10) at 7.6 m for 50 mm, 11.4 m for 75 mm, 15.6 m for 100 mm, and 25 m for 150 mm, and HVBT-16-A(B10) at 15.6 m for a 200 mm width.
Catalog suffixes stay with the page that printed them
As of November 11, 2026, the TE product page lists HVBT-12-A(B10), TE part CM6536-000, at 25 mm, for Europe, Middle East, and Africa. HVBT-14-A(B10), CS5522-000, is 50 mm and listed as worldwide. HVBT-16-A(B10), CM6538-000, is 100 mm, for Europe, Middle East, and Africa. The Americas rows on that page are HVBT-1-R-01(B8), CM6539-000, at 25 mm; HVBT-2-R-01(B4), CP8406-000, at 50 mm; and HVBT-4-R-01(B2), CM6541-000, at 100 mm. The same page prints the line that this product is not currently available. EPP-2660's length table prints HVBT-12-A(B20) on the 25 mm row, while the product page prints HVBT-12-A(B10) and HVBT-1-R-01(B8) at 25 mm. Copy the suffix from the document the order cites. Clearance for BBIT tubing is on the BPTM and BBIT page.
What to copy onto the tape line
- Tape: Scotch 2228, or Raychem HVBT, as opened November 11, 2026.
- 2228 bus connection: up to 35 kV, 3M drawing 2047B-106, 1.65 mm, 90°C normal, 130°C short-term.
- 2228 cable or motor lead: the 1000 V line on the same sheet.
- 2228 build: half-lap, stretch to 3/4 width, then two half-lapped layers of Scotch vinyl.
- HVBT: one two-thirds overlap for at least 17.5 kV, or a second layer for 36 kV.
- HVBT temperature: -40°C to 90°C, from the product page opened November 11, 2026.
- HVBT width: 25 mm, 50 mm, or 100 mm, and the suffix from the page the order cites.
- Availability: the product page printed that HVBT is not currently available.
Questions the two tape sheets answer
Is 35 kV the cable rating on Scotch 2228?
The bus bar connection line is up to 35 kV, as of November 11, 2026, and it cites drawing 2047B-106. The cable, wire, and motor-lead lines on the same sheet are up to 1000 volts.
How many HVBT layers match 36 kV?
EPP-2660 and the product page say a second layer brings the AC withstand to 36 kV, as of November 11, 2026. One layer, two-thirds overlapped, is at least 17.5 kV.
Which 25 mm HVBT suffix is the order?
The product page prints HVBT-12-A(B10) and HVBT-1-R-01(B8) at 25 mm, as of November 11, 2026. EPP-2660's length table prints HVBT-12-A(B20) for a 25 mm rectangular bar. Copy the suffix from the document on the order.
Sources
The 1.65 mm thickness, the 35 kV busbar line, drawing 2047B-106, the 1000 V cable line, and the 90°C and 130°C classification are from the 3M Scotch 2228 datasheet, issue 10.12.2018. The 17.5 kV and 36 kV layer sentence, the -40°C to 90°C range, the widths, the part numbers, and the availability line are from the TE HVBT product page. The backing-material tests and the length table are from EPP-2660-10/18. All three were opened November 11, 2026.