Belden 3109A PVC or 3109DB CPE Direct Burial

Use 3109A for the 4-pair PVC jacket at 0.448 in and 60°C. Use 3109DB for the CPE direct-burial jacket at 0.481 in and 90°C. Both list 120 Ohm and 2.7 A at 25°C.

Rust Belt Industrials · October 28, 2026 · 6 min read

On this page

Use Belden 3109A when the 4-pair 22 AWG cable is the industrial PVC jacket. As of October 28, 2026, that sheet lists a nominal diameter of 0.448 in (11.4 mm), UL temperature 60°C, operating temperature -20°C to +60°C, and 2.7 A per conductor at 25°C. Use Belden 3109DB when the cable is the CPE direct-burial jacket. As of the same day, that sheet lists a nominal diameter of 0.481 in (12.2 mm), UL temperature 90°C, operating temperature -40°C to +90°C, and the same 2.7 A per conductor at 25°C. Both sheets list 120 Ohm and conductor DCR of 14.7 Ohm/1000ft. The April 2022 line card lists 3109A as industrial PVC, CM/PLTC, and 3109DB as CPE, CM/PLTC, UL Direct Burial. Three pairs of the PVC and CPE constructions are 3108A and 3108DB, on the 3108A and 3108DB page.

PVC and CPE are separate rows at four pairs

As of October 28, 2026, the line card lists 3109A at 4 pair, 22 AWG, industrial PVC, CM/PLTC, industrial and other harsh environment. The burial block lists 3109DB at 4 pair, 22 AWG, CPE, CM/PLTC, UL Direct Burial, and the same harsh-environment column. 3109A's product note says a CPE jacketed version is ordered as YR44768. That page was not opened. 3109DB is the direct-burial CPE sheet opened for this comparison. YR44768 stays the number in the 3109A note. The same line card also names 3109T and 3109Z. Those sheets were not opened, so this page does not assign them a diameter or a listing.

Four 22 AWG pairs, with the jacket and water block from the sheet

As of October 28, 2026, both sheets list four pairs of 22 AWG (7x30) tinned copper, foam polyethylene insulation of 0.023 in (0.58 mm), a nominal insulation diameter of 0.075 in (1.9 mm), notes HDPE, and the blue, orange, green, and brown stripe pairs. Both shields are a 100% bi-laminate tape, a 22 AWG (7x30) tinned-copper drain, and a 65% tinned-copper braid. 3109DB adds a waterblock tape. 3109A does not print a waterblocking line. 3109A's jacket is PVC, 0.053 in (1.3 mm), nominal diameter 0.448 in (11.4 mm). 3109DB's jacket is CPE, chlorinated polyethylene, 0.053 in (1.3 mm), nominal diameter 0.481 in (12.2 mm). The 3109DB product description names Datalene insulation and prints DIR BUR in the title block. The construction cell still says foam polyethylene, notes HDPE.

3109A and 3109DB rows from the sheets opened October 28, 2026.
Item3109A3109DB
Line-card jacketIndustrial PVCCPE, UL Direct Burial
Nominal jacket OD0.448 in (11.4 mm)0.481 in (12.2 mm)
UL temperature60°C90°C
Operating range-20°C to +60°C-40°C to +90°C
Current2.7 A per conductor at 25°C2.7 A per conductor at 25°C
Conductor DCR14.7 Ohm/1000ft14.7 Ohm/1000ft
Outer-shield DCR2.53 Ohm/1000ft (8.30 Ohm/km)2.95 Ohm/1000ft (9.68 Ohm/km)
Water blockNot printedWaterblock tape
Oil noteOil Res IIOil Res I and II

120 Ohm and 2.7 A at 25°C on both sheets

As of October 28, 2026, both sheets list conductor DCR of 14.7 Ohm/1000ft, capacitance of 11 pF/ft (36 pF/m) conductor to conductor and 20.9 pF/ft (68.6 pF/m) conductor to other, impedance of 120 Ohm, velocity of 78%, insertion loss of 0.5 dB/100ft at 1 MHz, and 2.7 A per conductor at 25°C. Voltage is 300 V (CM, PLTC) on both. 3109A prints inductance of 0.225 µH/ft (0.738 µH/m). The 3109DB electrical row prints the DCR, capacitance, impedance, velocity, and current cells and does not print an inductance number. Outer-shield DCR is 2.53 Ohm/1000ft (8.30 Ohm/km) on 3109A and 2.95 Ohm/1000ft (9.68 Ohm/km) on 3109DB. The oil note on 3109A says the cable passes Oil Res II per UL 1277, Table 10.17. The oil note on 3109DB says it passes Oil Res I and II per the same table. Copy the oil line and the shield-DCR cell from the sheet you named. The 3-pair current cell, 4.2 A at 30°C, stays on the 3108A and 3109A page.

Direct burial is the title, the applications line, and the line card

3109DB's title includes Sun Res and Dir Bur, as of October 28, 2026. The applications cell includes direct burial and outdoor uses such as solar and lighting. The suitability cell lists indoor, outdoor, sunlight resistance, and oil resistance. It does not repeat the words direct burial. The line card is the page that prints UL Direct Burial on the 3109DB row. 3109A's suitability cell is indoor, outdoor, sunlight resistance, and oil resistance, and its title does not say Dir Bur. Installation temperature is printed on 3109DB, -20°C to +90°C. 3109A does not print an installation-temperature cell.

As of October 28, 2026, 3109A lists minimum bend radius 5.5 in (140 mm) for stationary use and for installation, maximum pull tension 100 lbs (45 kg), and weight 82 lbs/1000ft. 3109DB lists minimum bend radius 4.8 in (120 mm) for stationary use and for installation, maximum pull tension 80 lbs (36 kg), and weight 86 lbs/1000ft. Neither weight cell prints a kilogram. Flammability on both is UL 1685 UL Loading, FT1, and IEC 60332-1-2. NEC compliance is Article 725, Article 800, CM, PLTC. CEC compliance is CM. 3109A prints CPR Euroclass Eca, CPR UKCA Class Eca, and a UKCA Mark line. 3109DB does not print a CPR line or a UK regulation line. 3109A page revision is 0.552, dated 02-20-2026. Black reels are 3109A 0101000 at 1,000 ft and 3109A 0102000 at 2,000 ft, both with footnote C for a crate reel, and 3109A 0105000 at 5,000 ft, which does not print that footnote. 3109DB page revision is 0.385, dated 10-07-2026. That sheet does not print a variant table.

What to copy onto the cable line

  • Part: 3109A or 3109DB, from the sheet opened October 28, 2026.
  • Jacket: PVC at 0.448 in (11.4 mm), or CPE at 0.481 in (12.2 mm).
  • Burial: Dir Bur on the 3109DB title and applications line, and UL Direct Burial on the April 2022 line card.
  • Temperature: UL 60°C and -20°C to +60°C, or UL 90°C and -40°C to +90°C, plus the installation cell on 3109DB.
  • Current and impedance: 2.7 A per conductor at 25°C, and 120 Ohm, on the part you named.
  • Shield DCR and oil: 2.53 Ohm/1000ft and Oil Res II, or 2.95 Ohm/1000ft and Oil Res I and II.

3109A or 3109DB note

Name the 4-pair part and copy the jacket, diameter, and temperature line from that sheet.

This prepares a request. It does not send one.

Questions these sheets answer

Does the burial jacket change the 2.7 A cell?

Both sheets print 2.7 A per conductor at 25°C and 120 Ohm, as of October 28, 2026. Jacket, diameter, UL temperature, shield DCR, pull tension, and the oil line are the cells that differ.

Is YR44768 the same part as 3109DB?

3109A's note names YR44768 for a CPE jacket, as of October 28, 2026. That page was not opened. 3109DB is the direct-burial sheet, with Dir Bur in the title and a waterblock tape. The request names the number on the sheet it is copying.

Which cell says direct burial?

The 3109DB title and applications cell say direct burial, as of October 28, 2026. The suitability cell lists sunlight and oil and does not repeat those two words. The line card prints UL Direct Burial. Copy the title and the line-card rating together when the drawing asks for the burial listing.

Sources

Jacket, diameter, temperature, current, oil, shield DCR, and the waterblock line are from the Belden 3109A and 3109DB technical data sheets. The industrial PVC row and the CPE UL Direct Burial row are from the Belden RS-485 line card dated April 2022. All three were opened October 28, 2026. YR44768, 3109T, and 3109Z were named and not opened.