Industrial networking
Belden 3082A PVC or 3083A CPE for DeviceNet Thick
Use 3082A for Thick PVC at 0.480 in, 16 A on the power pair, and 60°C. Use 3083A for Thick CPE at 0.476 in, 24 A on the power pair, and 105°C.
On this page
Use Belden 3082A when the ODVA Class 2 Thick cable is the PVC jacket. As of October 29, 2026, that sheet lists a nominal jacket diameter of 0.480 in (12.2 mm), 16 A per power conductor at 30°C, UL temperature 60°C, and operating temperature -20°C to +60°C. Use Belden 3083A when the Thick cable is the CPE jacket. As of the same day, that sheet lists a nominal jacket diameter of 0.476 in (12.1 mm), 24 A per power conductor at 30°C, UL temperature 105°C, and operating temperature -20°C to +105°C. Both are 15 AWG power and 18 AWG data. Both data pairs list 120 Ohm and 14 A per conductor at 30°C. Thick versus Thin, 3082A against 3084A, is on the Thick and Thin page.
Both sheets say Class 2 Thick, and the jacket compound is the split
As of October 29, 2026, the other-standard cell on 3082A and on 3083A says ODVA Class 2 Thick. Both descriptions say DeviceBus for ODVA DeviceNet, two pair, 15 plus 18 AWG stranded tinned copper, PVC and foam polyethylene insulation, individual Beldfoil, and an overall tinned-copper braid at 65%. 3082A's description ends in a PVC jacket listed CMG PLTC-ER. 3083A's description ends in a CPE jacket listed CMG PLTC. The power pair on both is 15 AWG, 19x27, tinned copper, PVC insulation, red and black, 0.021 in (0.53 mm) thick, nominal insulation diameter 0.109 in (2.77 mm). The data pair on both is 18 AWG, 19x30, tinned copper, foam polyethylene, blue and white, 0.053 in (1.3 mm) thick, nominal insulation diameter 0.150 in (3.81 mm), and the notes cell says HDPE. Each pair has a 100% bi-laminate tape. The braid is 65% tinned copper with an 18 AWG (19x30) tinned-copper drain.
0.480 in PVC or 0.476 in CPE, and the listing lines that do not match
As of October 29, 2026, 3082A's jacket is PVC, 0.060 in (1.5 mm) thick, nominal diameter 0.480 in (12.2 mm), jacket OD tolerance plus or minus 0.010 in. 3083A's jacket is CPE, 0.058 in (1.5 mm) thick, nominal diameter 0.476 in (12.1 mm), jacket OD tolerance plus or minus 0.015 in. 3082A's UL voltage cell is 300 V (CMG, PLTC-ER) and 600 V (AWM 20201), plus a second voltage cell of 300 V (AWM I/II A). Its NEC / UL cell is Article 725, Article 800, CMG, PLTC. The description says PLTC-ER. The NEC cell does not print ER. 3083A's UL voltage cell is 300 V (CMG, PLTC-ER). Its description says CMG PLTC. Its NEC / UL cell is Article 725, Article 800, CMG, PLTC. Those three 3083A lines do not use one listing phrase. Copy the voltage cell, the description, and the NEC cell as three lines. 3083A does not print an AWM line.
| Item | 3082A | 3083A |
|---|---|---|
| ODVA line | Class 2 Thick | Class 2 Thick |
| Jacket | PVC, 0.480 in | CPE, 0.476 in |
| Power current | 16 A at 30°C | 24 A at 30°C |
| Data current | 14 A at 30°C | 14 A at 30°C |
| Data impedance | 120 Ohm | 120 Ohm |
| UL temperature | 60°C | 105°C |
| Operating range | -20°C to +60°C | -20°C to +105°C |
| Suitability | Oil resistance, no burial cell | Burial, no oil cell |
Data stays 14 A and 120 Ohm, and the power current changes
As of October 29, 2026, both sheets list nominal power-conductor DCR of 3.58 Ohm/1000ft, nominal data-conductor DCR of 7.2 Ohm/1000ft (24 Ohm/km), inner-shield DCR of 5.75 Ohm/1000ft (18.9 Ohm/km) on the power pair and 3.58 Ohm/1000ft (11.7 Ohm/km) on the data pair, and outer-shield DCR of 7.29 Ohm/1000ft (23.9 Ohm/km). Data-pair capacitance is 12 pF/ft (39 pF/m). Data-pair impedance is 120 Ohm. Data-pair velocity is 75%. Data-pair current is 14 A per conductor at 30°C on both. Power-pair current is 16 A per conductor at 30°C on 3082A and 24 A per conductor at 30°C on 3083A. 3082A also prints power-pair inductance of 0.174 µH/ft (0.571 µH/m) and data-pair delay of 1.36 ns/ft. 3083A does not print an inductance cell or a delay cell. The power-pair impedance cell is empty on both, so 120 Ohm stays on the data pair.
60°C and oil on the PVC sheet, 105°C and burial on the CPE sheet
As of October 29, 2026, 3082A lists UL temperature 60°C, operating temperature -20°C to +60°C, bend radius 5.76 in (146 mm), pull tension 192.6 lbs (87.36 kg), and weight 128 lbs/1000ft. Suitability is indoor, outdoor, sunlight resistance, and oil resistance. Flammability is UL 1685 FT4 Loading, IEEE 1202 FT4, and IEC 60332-1-2. CPR is Euroclass Eca. 3083A lists UL temperature 105°C, operating temperature -20°C to +105°C, bend radius 5.712 in (145.1 mm), the same pull tension of 192.6 lbs (87.36 kg), and weight 127 lbs/1000ft. Suitability is indoor, outdoor, sunlight resistance, and burial. The sheet does not print oil resistance. Flammability is UL 1685 FT4 Loading and IEEE 1202 FT4. It does not print IEC 60332-1-2. CPR is Euroclass Fca. Both notes say the jacket is printed 1PR16 instead of 1PR15 because of the UL CMG listing, and both notes begin with the word Thick. Page revision is 0.607 on 3082A and 0.564 on 3083A, both dated 02-20-2026.
What to copy onto the cable line
- Part: 3082A or 3083A, from the sheet opened October 29, 2026.
- ODVA line: Class 2 Thick on both.
- Jacket: PVC at 0.480 in, tolerance 0.010 in, or CPE at 0.476 in, tolerance 0.015 in.
- Power current: 16 A at 30°C, or 24 A at 30°C. Data current: 14 A at 30°C on both.
- Data impedance: 120 Ohm. Leave the power-pair impedance blank.
- Temperature: 60°C and -20°C to +60°C, or 105°C and -20°C to +105°C.
- Listing lines: copy the voltage cell, the description, and the NEC cell separately when they disagree.
- Suitability: oil resistance on 3082A, or burial on 3083A.
Questions these sheets answer
Does the CPE sheet keep 16 A?
3082A lists 16 A per power conductor at 30°C, as of October 29, 2026. 3083A lists 24 A per power conductor at 30°C. The data-pair current stays 14 A on both.
Which 3083A line says PLTC-ER?
3083A's voltage cell prints 300 V (CMG, PLTC-ER), as of October 29, 2026. The description says CMG PLTC, and the NEC cell says CMG, PLTC. The page keeps all three.
Does 120 Ohm pick PVC or CPE?
Both data pairs list 120 Ohm, as of October 29, 2026. The jacket compound, the power current, and the temperature pick 3082A or 3083A.
Sources
Class, jacket, current, impedance, temperature, listing, and suitability are from the Belden 3082A and 3083A technical data sheets. Both were opened October 29, 2026. Inner-shield DCR is on the sheets and is named above. Max-conductor DCR is not a column on these two Thick sheets.