Beckhoff ZB7005 EtherCAT P or ZB9013 Fixed PVC

Use ZB9013 for fixed yellow PVC at 6.5 mm. Use ZB7005 for EtherCAT P PUR drag chain at 5.7 mm and AWG24.

Rust Belt Industrials · October 25, 2026 · Updated October 26, 2026 · 8 min read

On this page

Use Beckhoff ZB9013 when the cable is the fixed yellow PVC line. As of October 25, 2026, the product-page technical-data cell is 1 x 4 x 0.34 mm² (AWG22), the jacket is PVC, and the outer diameter is 6.5 mm ± 0.2 mm. Use Beckhoff ZB7005 when the cable is EtherCAT P drag chain. As of the same day, the ZB7005 sheet lists 1 x 4 x 0.25 mm2 (AWG24), a PUR jacket, an outer diameter of 5.7 mm ± 0.3 mm, and a characteristic impedance of 100 Ω ± 15 Ω. The ZB9013 title still reads 2 x 2 x AWG22. Copy the technical-data cell and keep the title string on the request. A green PROFINET article at 6.3 mm is a different comparison, on the ZB9013 and 2170891 page.

The ZB9013 title and the technical-data cell still differ

The ZB9013 product page opened October 25, 2026 titles the cable 2 x 2 x AWG22, fixed installation, Cat.5, yellow. A line under that title reads 1 x 4 x AWG22, fixed installation, Cat.5, yellow. The technical-data table reads 1 x 4 x 0.34 mm² (AWG22). The print PDF opened the same day still carries both: the category line is 2 x 2 x AWG22, a body line is 1 x 4 x AWG22, and the technical-data cell is 1 × 4 × 0.34mm2 (AWG22). The diameter on the PDF matches the product page, 6.5 mm ± 0.2 mm. This page does not pick one construction string. The request copies 1 x 4 x 0.34 mm² (AWG22) from the technical-data cell and records that the title and the PDF category line still say 2 x 2 x AWG22.

ZB9013's other technical-data cells, as of October 25, 2026, are use fixed installation, jacket PVC, outer diameter 6.5 mm ± 0.2 mm (0.2559 in ± 0.0079 in), moved bend 7.5 times the outer diameter, fixed bend 3 times the outer diameter, and jacket color yellow. It is sold by the meter. Product status is regular delivery. Halogen-free is no. REACH SVHC is no. POP is compliant. RoHS is compliant without exemption. The product page says further details are on the data sheet. The print PDF does not add a temperature or an impedance.

The ZB7005 sheet, footer dated 01/2026 and opened October 25, 2026, lists a star quad, 19-strand tinned-copper conductors, and cross-section 1 x 4 x 0.25 mm2 (AWG24). Outer diameter is 5.7 mm ± 0.3 mm (0.2244 in ± 0.0118 in). The shield is aluminum-clad foil and a braid of tinned copper, with an optical covering of at least 85%. Use is drag-chain suitable. Jacket color is black, similar to RAL 9005, with a red stripe similar to RAL 3020. Jacket material is PUR, described as halogen-free, flame-retardant, matt, and low adhesion. Wire colors are yellow, orange, white, and blue. Wire insulation is PO. The sheet is sold by the meter, with length tolerances of 2 to 3%.

ZB9013 and ZB7005 from the Beckhoff pages opened October 25, 2026. ZB9013 impedance was not on the product page or the print PDF.
ItemZB9013ZB7005
Cross-section cell1 x 4 x 0.34 mm² (AWG22). Title also says 2 x 2 x AWG22.1 x 4 x 0.25 mm2 (AWG24)
UseFixed installationDrag-chain suitable
JacketPVC, yellow, halogen-free noPUR, black with a red stripe
Outer diameter6.5 mm ± 0.2 mm5.7 mm ± 0.3 mm
ImpedanceNot printed on the page or the print PDF100 Ω ± 15 Ω, labeled Ethernet
Moved bend7.5 x outer diameter10 x outer diameter. Drag-chain cell is separate.
Fixed bend3 x outer diameter4 x outer diameter

ZB7005 prints several voltage lines, each with its own label

The ZB7005 electrical table, as of October 25, 2026, lists rated voltage 30 V and operating voltage at most 300 V. Insulation resistance is at least 5G Ω * km, printed with that spacing. Unbalanced capacitance to ground is at most 2000 pF/km. Mutual capacitance is nom. 50 nF/km. Characteristic impedance, labeled Ethernet, is 100 Ω ± 15 Ω. Dielectric strength wire to wire and wire to shield is 1.5 kV at 50 Hz for 1 minute. Signal running time is under 520 ns/100 m. Electrical parameters are based on Cat.5. Test voltage is 2000 V, 50 Hz, 1 minute. Those lines stay labeled. They are not one rating.

The jacket print includes Cat5e 4xAWG24/19, E63216, AWM 22203, and AWM I A/B 80°C 600V FT2. Approvals are c(UL)us AWM Style 22203. The UL E-file number is E63216. The application note says the cable has a 600 V approval according to AWM Style 22203. That 600 V line is the approval sentence. It is not the 30 V rated-voltage cell. Moved operation is -20°C to +80°C (-4°F to +176°F). Fixed operation is -40°C to +80°C (-40°F to +176°F). LABS-free is yes. Flame tests named are VW-1, UL 1581 section 1080, and IEC 60332-1-2. Halogen-free is according to IEC 60754 or DIN VDE 0472 part 815. The attenuation rows stay off this comparison. At 62.5 MHz the dB/100 m cell prints 62.5 beside 19.1 dB/100 ft.

75 m, 100 m, and 3 A sit on different Beckhoff pages

The EtherCAT P overview opened October 25, 2026 says communication and power share a 4-wire Ethernet cable. US, the system and sensor supply, and UP, the peripheral voltage for actuators, are electrically isolated, and each can supply up to 3 A at 24 V DC. The overview says cable lengths up to 75 meters are possible, and it names industrial Cat.5 cables in AWG22 and AWG24. It also names an M8 P-coded connector according to IEC 61076-2-114, and a connector family meant to avoid mating with standard EtherCAT slaves. A later sentence on that overview covers drives up to 630 V AC or 850 V DC and up to 72 A. That sentence is about the connector family. It is not a cell on the ZB7005 electrical table. The 3 A figure is on the overview. It is not on the ZB7005 sheet.

The EtherCAT wiring page opened October 25, 2026 says the cable length between two EtherCAT devices must not exceed 100 m, and that the cable should meet at least category 5 according to EN 50173 or ISO/IEC 11801. EtherCAT uses 4 wires. The pin table is pin 1 yellow TD+, pin 2 orange TD-, pin 3 white RD+, and pin 6 blue RD-. Those color names match the four colors on the ZB7005 sheet. The ZB7005 sheet does not print pin numbers, and the wiring page's connector in that section is RJ45. The suitable-cable list on the wiring page names ZB9010 for fixed installation, CAT 5e, 4-core, and ZB9020 for drag chain, CAT 5e, 4-core. It does not name ZB9013 or ZB7005. Outer diameter, jacket, and bend for ZB9010 and ZB9020 are on the ZB9010 and ZB9020 page. Pair colors for a 4-core PROFINET cable are on the pair-color page.

Bend multipliers and the cycle counts are separate cells

ZB9013, as of October 25, 2026, prints a moved bend of 7.5 times the outer diameter and a fixed bend of 3 times the outer diameter. The diameter those multipliers use is 6.5 mm ± 0.2 mm. The page does not print a cycle count.

ZB7005 prints a moved bend of 10 times the outer diameter, and a fixed bend of 4 times the outer diameter. A separate drag-chain cell prints 7 times the outer diameter for 2 million cycles, 10 times for 5 million cycles, and 15 times for 10 million cycles. The cycle cell also prints 10 million cycles at R = 90 mm, 5 million at R = 60 mm, 2 million at R = 40 mm, and 5 million with 30 x D at v = 2 m/s and a = 30 m/s2. The title and the application note both name a 40 mm bend. The moved-bend multiplier and the 40 mm radius are both on the sheet. This page does not multiply 10 by 5.7 mm.

What to copy onto the cable line

  • Part: ZB9013 or ZB7005, from the page opened October 25, 2026.
  • Cross-section: 1 x 4 x 0.34 mm² (AWG22) from the ZB9013 technical-data cell, with the title string 2 x 2 x AWG22 recorded, or 1 x 4 x 0.25 mm2 (AWG24) on ZB7005.
  • Jacket and diameter: yellow PVC at 6.5 mm ± 0.2 mm, or PUR at 5.7 mm ± 0.3 mm.
  • Motion: fixed installation, or drag chain, with the bend cell you are copying.
  • Length rule from the page you are following: up to 75 m on the EtherCAT P overview, or 100 m on the EtherCAT wiring page.
  • Voltage, on ZB7005, with its label: 30 V rated, at most 300 V operating, or the 600 V AWM 22203 line.

ZB7005 or ZB9013 note

Name the cable and the cross-section cell you are copying.

This prepares a request. It does not send one.

Questions these Beckhoff pages answer

Which ZB9013 construction string goes on the request?

Copy the technical-data cell, 1 x 4 x 0.34 mm² (AWG22), as of October 25, 2026. Record that the H1 and the print-PDF category line still say 2 x 2 x AWG22. The print PDF did not retire either string.

Is 3 A a ZB7005 cable rating?

Up to 3 A at 24 V DC, for US and for UP, is on the EtherCAT P overview. The ZB7005 electrical table prints 30 V rated and at most 300 V operating. Put 3 A on the request only when the overview is the page being followed, and keep it off the cable's voltage line.

Does the 100 m wiring rule set the EtherCAT P length?

The wiring page limits the link between two EtherCAT devices to 100 m. The EtherCAT P overview says lengths up to 75 meters are possible. ZB7005's sheet does not print either distance. The request names the page whose length rule it is using.

Sources

ZB7005 cross-section, diameter, impedance, voltage labels, bend, and cycle counts are from the ZB7005 data sheet. ZB9013 technical data, the title string, compliance, and product status are from the ZB9013 product page. The print PDF confirms that the title string and the technical-data cell still differ. The 3 A and 75 m sentences are from the EtherCAT P overview. The 100 m rule, the RJ45 pin colors, and the ZB9010 and ZB9020 names are from the EtherCAT wiring page. All five were opened October 25, 2026. ZB9010 and ZB9020 sheets were opened October 26, 2026, and their diameters are on that comparison. The ZB7005 attenuation table was not used.