Skip to the guide

Industrial networking

Belden 9463 PVC or 89463 FEP for Blue Hose

Use 9463 for the PVC Blue Hose at 0.238 in, UL 80°C, and 300 V (CM, CL2). Use 89463 for the FEP Blue Hose at 0.203 in, UL 200°C, and 300 V (CMP, CL2P). Both list 78 Ohm and 20 AWG.

Rust Belt Industrials · November 3, 2026 · 5 min read

On this page

Use Belden 9463 when Data Highway Plus is the PVC Blue Hose. As of November 3, 2026, that sheet lists a nominal jacket diameter of 0.238 in (6.05 mm), UL temperature 80°C, an operating range of -40°C to +80°C, and 300 V (CM, CL2) together with 300 V (UL AWM 2464). Use Belden 89463 when the sheet that names 9463 as its non-plenum number is the FEP jacket. As of the same day, that sheet lists a nominal jacket diameter of 0.203 in (5.16 mm), UL temperature 200°C, an operating range of -70°C to +200°C, and 300 V (CMP, CL2P). Both list one 20 AWG pair, impedance of 78 Ohm, and Allen Bradley part number 1770-CD. 9463's plenum-number cell is 89463.

20 AWG twinax, polyethylene and PVC, or FEP and FEP

As of November 3, 2026, both sheets list one pair of 20 AWG 7x28 tinned copper, insulation colors clear and blue, and a note of twinax with rod fillers. 9463 insulation is polyethylene, 0.019 in (0.48 mm), nominal insulation diameter 0.0755 in (1.92 mm). The description says a tinned-copper braid of 55%. The coverage cell says 60%. The drain is 20 AWG (7x28) tinned copper on a 100% bi-laminate tape. The jacket cell is PVC, 0.037 in (0.94 mm), nominal diameter 0.238 in (6.05 mm), with a jacket OD note of plus or minus 0.003. 89463 insulation is FEP, 0.0175 in (0.445 mm), nominal insulation diameter 0.073 in (1.9 mm). The description and the coverage cell both say a tinned-copper braid of 76%. The drain gauge matches. The jacket cell is FEP, 0.015 in (0.38 mm), nominal diameter 0.203 in (5.16 mm). 89463 does not print an OD tolerance. The 55% description and the 60% coverage cell on 9463 stay as two strings.

9463 and 89463 rows from the technical data sheets opened November 3, 2026.
Item946389463
JacketPVC, 0.238 inFEP, 0.203 in
Braid coverage cell60%76%
Impedance78 Ohm78 Ohm
Conductor DCR9.5 Ohm/1000ft9.5 Ohm/1000ft
Velocity66%69%
UL temperature80°C200°C
Voltage300 V (CM, CL2), AWM 2464300 V (CMP, CL2P)
Cross-referencePlenum number 89463Non-plenum number 9463

78 Ohm and 9.5 Ohm/1000ft match, and the delay does not

As of November 3, 2026, both sheets list conductor DCR of 9.5 Ohm/1000ft, outer-shield DCR of 4.1 Ohm/1000ft (13 Ohm/km), capacitance conductor to conductor of 19.7 pF/ft (64.6 pF/m), inductance of 0.12 µH/ft (0.39 µH/m), and impedance of 78 Ohm. 9463 also prints 37 pF/ft (120 pF/m) and 36 pF/ft (120 pF/m). Both of those cells show 120 pF/m, so the shared capacitance on this page is the conductor-to-conductor cell. 89463 prints one conductor-to-shield cell of 37 pF/ft (120 pF/m) and does not print the 36 pF/ft cell. Delay is 1.54 ns/ft on 9463 and 1.47 ns/ft on 89463. Velocity is 66% on 9463 and 69% on 89463. Attenuation on both, in dB/100ft, is 0.6 at 1 MHz, 2.1 at 10 MHz, 5.0 at 50 MHz on 9463 and 5 at 50 MHz on 89463, then 7.5 at 100 MHz, 11.0 at 200 MHz on 9463 and 11 at 200 MHz on 89463, and 16.0 at 400 MHz on 9463 and 16 at 400 MHz on 89463. Voltage on 9463 is 300 V (CM, CL2) and 300 V (UL AWM 2464). NEC / UL compliance is Article 725, Article 800, CM, CL2. AWM compliance is AWM 2464. CEC compliance is CM. 89463's voltage is 300 V (CMP, CL2P). NEC / UL compliance is Article 725, Article 800. CEC compliance is CMP. 89463 does not print an AWM line.

MSHA and AWM 2464 are on 9463

As of November 3, 2026, 9463's other-standard cell prints P-7K-SC-182141-MSHA and Allen Bradley part number 1770-CD. 89463's other-standard cell prints Allen Bradley part number 1770-CD and does not print the MSHA string. 9463 suitability is indoor, outdoor, and sunlight resistance. UL temperature is 80°C. Operating, installation, and storage are each -40°C to +80°C. Bend radius is 2.4 in (61 mm). Pull tension is 48 lbs (22 kg). Bulk weight is 36 lbs/1000ft. Flammability is UL 1685 UL Loading and IEC 60332-1-2. 89463's applications line says extreme temperature, oil and gasoline, harsh environment, and the Data Highway uses. Suitability is indoor. UL temperature is 200°C. Operating temperature is -70°C to +200°C. The sheet does not print installation or storage columns. Bend radius is 2.5 in (64 mm). Pull tension is 48 lbs (22 kg). Bulk weight is 34 lbs/1000ft. Flammability is NFPA 262, UL 910 (Plenum), FT6, and IEC 60332-1-2. Page revision is 0.616, dated 02-20-2026, on both sheets.

The 9463 description says blue, and the table lists more colors

As of November 3, 2026, 9463's product description says a blue PVC outer jacket. The variant table lists blue, blue strong, brown, orange, and violet put-ups. Orange rows include 9463 0031000 at 1,000 ft and 9463 00312000 at 2,000 ft. Violet includes 9463 0071000 at 1,000 ft. 89463's description says a blue FEP outer jacket. Its variant rows are blue, light: 89463 0061000 at 1,000 ft and 89463 0062500 at 2,500 ft, both footnote C. The jacket compound comes from the material cell. The put-up color comes from the row being ordered.

What to copy onto the cable line

  • Part: 9463 or 89463, from the sheet opened November 3, 2026.
  • Pair: 1 of 20 AWG 7x28, clear and blue, twinax with rod fillers.
  • Braid coverage cell: 60% on 9463, or 76% on 89463. 9463's description also says 55%.
  • Jacket: PVC at 0.238 in, or FEP at 0.203 in.
  • Impedance: 78 Ohm. Conductor DCR: 9.5 Ohm/1000ft. Both sheets.
  • Delay: 1.54 ns/ft, or 1.47 ns/ft. Velocity: 66%, or 69%.
  • Temperature: UL 80°C and -40°C to +80°C, or UL 200°C and -70°C to +200°C.
  • Voltage: 300 V (CM, CL2) and AWM 2464, or 300 V (CMP, CL2P).
  • Other standard: 1770-CD on both. MSHA string P-7K-SC-182141-MSHA on 9463 only.

9463 or 89463 note

Name the Blue Hose part and copy the jacket, temperature, and voltage from that sheet.

This prepares a request. It does not send one.

Questions these sheets answer

Does the FEP jacket keep 78 Ohm?

Both sheets print 78 Ohm, as of November 3, 2026. Diameter, velocity, delay, and the voltage cell still change.

Which braid percent is on 9463?

9463's description says 55%, as of November 3, 2026. The coverage cell says 60%. 89463's description and coverage cell both say 76%.

Which sheet prints the MSHA string?

9463 prints P-7K-SC-182141-MSHA, as of November 3, 2026. 89463's other-standard cell prints 1770-CD and does not print that MSHA string.

Sources

Jacket, impedance, temperature, voltage, and the cross-reference numbers are from the Belden 9463 and 89463 technical data sheets. Both were opened November 3, 2026. 9463 prints two capacitance cells that both show 120 pF/m. The shared figure used here is 19.7 pF/ft (64.6 pF/m).