Industrial networking
Belden 8723 PVC at 52 Ohm or 88723 FEP at 40 Ohm
Use 8723 for the PVC CM jacket at 0.160 in and 52 Ohm. Use 88723 for the FEP CMP jacket at 0.15 in and 40 Ohm. Each sheet names the other.
On this page
Use Belden 8723 when the two-pair 22 AWG cable is the PVC jacket listed CM. As of November 3, 2026, that sheet lists a nominal jacket diameter of 0.160 in (4.06 mm), characteristic impedance of 52 Ohm, 2.8 A per conductor at 25°C, and UL temperature 60°C. Use Belden 88723 when the cable is the FEP jacket listed CMP. As of the same day, that sheet lists a nominal jacket diameter of 0.15 in (3.8 mm), characteristic impedance of 40 Ohm, the same 2.8 A per conductor at 25°C, and UL temperature 150°C with an operating range of -70°C to +200°C. 8723's plenum-number cell names 82723, 87723, and 88723. 88723's non-plenum number is 8723. The one-pair choice at 64 Ohm is on the 8761 and 8723 page.
PVC at 0.160 in, or FEP at 0.15 in
As of November 3, 2026, 8723's title is audio, control, and instrument, 22 AWG, 2 pair, PO, individual foil, PVC jacket, CM. The insulation cell is polypropylene, 0.009 in (0.23 mm) thick, nominal insulation diameter 0.046 in (1.2 mm). The jacket cell is PVC, 0.020 in (0.51 mm) thick, nominal diameter 0.160 in (4.06 mm). 88723's title names FEP insulation, individual foil, and an FEP jacket, CMP. The insulation cell is FEP, 0.007 in (0.18 mm), nominal insulation diameter 0.042 in (1.1 mm). The jacket cell is FEP, 0.015 in (0.38 mm), nominal diameter 0.15 in (3.8 mm). Both construction blocks list two pairs of 22 AWG 7x30 tinned copper, colors black and red, and green and white. Each pair has a 100% bi-laminate tape and a 24 AWG (7x32) tinned-copper drain. 8723's shield note says foil-out tape on each pair, one drain wire. 88723's drain note says each pair.
| Item | 8723 | 88723 |
|---|---|---|
| Jacket | PVC, 0.160 in | FEP, 0.15 in |
| Insulation cell | Polypropylene | FEP |
| Impedance | 52 Ohm | 40 Ohm |
| Current | 2.8 A at 25°C | 2.8 A at 25°C |
| UL temperature | 60°C | 150°C |
| Operating range | -20°C to +75°C | -70°C to +200°C |
| Listing | 300 V (CM) | 300 V (CMP) |
| Cross-reference | Plenum numbers include 88723 | Non-plenum number 8723 |
52 Ohm on the PVC sheet, 40 Ohm on the FEP sheet
As of November 3, 2026, 8723 lists conductor DCR of 18.2 Ohm/1000ft, inner-shield DCR of 18.38 Ohm/1000ft (60.30 Ohm/km), capacitance of 33 pF/ft (110 pF/m) and 62 pF/ft (200 pF/m), inductance of 0.17 µH/ft (0.56 µH/m), velocity of 66%, and impedance of 52 Ohm. The current cell is 2.8 A per conductor at 25°C. The high-frequency line prints 10 dB/100m and does not print a frequency. 88723 lists conductor DCR of 18.2 Ohm/1000ft, inner-shield DCR of 17.42 Ohm/1000ft (57.15 Ohm/km), capacitance of 35 pF/ft (110 pF/m) and 67 pF/ft (220 pF/m), velocity of 69%, and impedance of 40 Ohm. The current cell is also 2.8 A per conductor at 25°C. 88723 does not print an inductance cell and does not print that 10 dB/100m line. Voltage is 300 V (CM) on 8723 and 300 V (CMP) on 88723. NEC / UL compliance is Article 800, CM on 8723 and Article 800, CMP on 88723. CEC compliance follows the same CM or CMP word.
88723's operating high is 200°C, and the UL cell is 150°C
As of November 3, 2026, 8723 lists UL temperature 60°C and operating temperature -20°C to +75°C. Bend radius is 1.5 in (38 mm) on 88723, and 1.6 in (41 mm) on 8723, stationary and installation on each sheet. Pull tension is 42 lbs (19 kg) on both. Bulk weight is 17 lbs/1000ft on 8723 and 19 lbs/1000ft on 88723. 88723 lists UL temperature 150°C and operating temperature -70°C to +200°C. Those two 88723 cells do not share a high end. Suitability on 8723 is indoor. Suitability on 88723 is indoor, sunlight resistance, UV resistance, and oil resistance. Flammability on 8723 is UL 1685 FT4 Loading and IEC 60332-1-2. Flammability on 88723 is NFPA 262 (UL 910), FT6, and IEC 60332-1-2. The 88723 notes cell prints Non.conduit. Gas/vapor-tight jacket. Page revision is 0.576, dated 02-20-2026, on 8723, and 0.553, dated 09-07-2025, on 88723.
Chrome rows on 8723, red rows on 88723 with no length column
As of November 3, 2026, 8723 variant rows are chrome and include 8723 060100 at 100 ft, 8723 060500 at 500 ft, and 8723 0601000 at 1,000 ft with footnote C, crate reel put-up. 88723 variant rows are red: 88723 002100, 88723 0021000, 88723 002500, and 88723 0025000, each with a UPC and, where marked, footnote C. That 88723 table does not print a length. 87723 is also named in 8723's plenum-number cell. The 87723 technical-data URL did not return a data sheet on November 3, 2026, so this page does not assign 87723 a diameter. The other CMP jacket opened that day is 82723, on the 82723 and 88723 page.
What to copy onto the cable line
- Part: 8723 or 88723, from the sheet opened November 3, 2026.
- Pairs: 2 of 22 AWG 7x30, black/red and green/white, foil on each pair.
- Drain: 24 AWG (7x32). 8723's note says one drain wire. 88723's note says each pair.
- Jacket: PVC at 0.160 in, or FEP at 0.15 in.
- Impedance: 52 Ohm, or 40 Ohm.
- Current: 2.8 A per conductor at 25°C, on both sheets.
- Temperature: UL 60°C and operating -20°C to +75°C, or UL 150°C and operating -70°C to +200°C.
- Listing: 300 V (CM), or 300 V (CMP).
Questions these sheets answer
Does CMP keep 52 Ohm?
8723 prints 52 Ohm, as of November 3, 2026. 88723 prints 40 Ohm. The plenum-number cell is the cross-reference. It does not copy the Ohm value.
Does 88723's UL cell say 200°C?
88723's UL temperature is 150°C, as of November 3, 2026. The operating range on that sheet is -70°C to +200°C. The request can carry both cells.
Does 8723's title say polypropylene?
8723's title line says PO, as of November 3, 2026. The insulation cell says polypropylene. 88723's title and insulation cell both say FEP.
Sources
Jacket, impedance, current, temperature, and the cross-reference numbers are from the Belden 8723 and 88723 technical data sheets. Both were opened November 3, 2026. 87723 was named on 8723 and was not opened. 82723 was opened the same day for the page linked above.