Belden 87761 PVDF or 88761 FEP for the 0.116 in CMP Pair

Use 87761 for the PVDF jacket, FT6, and a suitability line of indoor and UV. Use 88761 for the FEP jacket, FT4, and a suitability line of indoor and outdoor. Both list 0.116 in, 42 Ohm, and 9 A.

Rust Belt Industrials · November 3, 2026 · 4 min read

On this page

Use Belden 87761 when the one-pair CMP cable at 0.116 in is the PVDF jacket. As of November 3, 2026, that sheet lists FT6, suitability of indoor and UV resistance, and bulk weight of 12 lbs/1000ft. Use Belden 88761 when that cable is the FEP jacket. As of the same day, that sheet lists FT4, suitability of indoor and outdoor, and bulk weight of 13 lbs/1000ft. Both list 42 Ohm, 9 A per conductor at 30°C, conductor DCR of 18.2 Ohm/1000ft, UL temperature 150°C, and an operating range of -20°C to +150°C. Both name 8761 as the non-plenum number. The PVC CMP sheet at 2.8 A is on the 82761 and 88761 page.

PVDF or FEP, both 0.014 in over the same FEP insulation

As of November 3, 2026, 87761's title says PVDF jacket, CMP. The jacket cell is polyvinylidene fluoride, 0.014 in (0.36 mm), nominal diameter 0.116 in (2.95 mm). 88761's title says FEP jacket, CMP. The jacket cell is fluorinated ethylene propylene, 0.014 in (0.36 mm), nominal diameter 0.116 in (2.95 mm). Both titles say 2 conductor, and the construction element is one pair of 22 AWG 7x30 tinned copper. Insulation on both is FEP, 0.007 in (0.18 mm), nominal insulation diameter 0.042 in (1.1 mm), colors black and red. The shield on both is a 100% bi-laminate tape with a 22 AWG (7x30) tinned-copper drain. Diameter, wall, colors, and drain match. The jacket polymer is the split.

87761 and 88761 rows from the technical data sheets opened November 3, 2026.
Item8776188761
JacketPVDF, 0.116 inFEP, 0.116 in
Impedance42 Ohm42 Ohm
Current9 A at 30°C9 A at 30°C
Conductor DCR18.2 Ohm/1000ft18.2 Ohm/1000ft
Shield DCR12.86 Ohm/1000ft12.86 Ohm/1000ft
UL temperature150°C150°C
Flammability markFT6FT4
SuitabilityIndoor, UV resistanceIndoor, outdoor

42 Ohm, 9 A, and 18.2 Ohm/1000ft match

As of November 3, 2026, both sheets list conductor DCR of 18.2 Ohm/1000ft, outer-shield DCR of 12.86 Ohm/1000ft (42.19 Ohm/km), capacitance of 35 pF/ft (110 pF/m) and 67 pF/ft (220 pF/m), inductance of 0.16 µH/ft (0.52 µH/m), and impedance of 42 Ohm. Current on both is 9 A per conductor at 30°C. Voltage on both is 300 V (CMP). NEC / UL compliance is Article 800, CMP. CEC compliance is CMP. Neither sheet prints a velocity. Neither prints AWM 2092. A request that only names 42 Ohm and 9 A still has to name PVDF or FEP, because those electrical cells do not pick the jacket.

The applications line is wider than the suitability cell

As of November 3, 2026, 87761's applications line says extreme high temperature, chemical resistance, outdoor and burial, and the low-voltage family. The suitability cell says indoor and UV resistance. It does not say outdoor. UL temperature is 150°C. Operating temperature is -20°C to +150°C. Flammability is NFPA 262, UL 910 (Plenum), FT6, and IEC 60332-1-2. Bend radius is 1.2 in (30 mm). Pull tension is 27.3 lbs (12.4 kg). Bulk weight is 12 lbs/1000ft. 88761's applications line says extreme high and low temperature, chemical resistance, outdoor and burial, and the same low-voltage family. The suitability cell says indoor and outdoor. It does not say burial. The notes say the cable is for indoor plenum environments and is also suitable for outdoor and underground applications. UL temperature, operating range, bend radius, and pull tension match 87761. Bulk weight is 13 lbs/1000ft. Flammability uses FT4 rather than FT6. 87761 does not print that Teflon note. Page revision is 0.531, dated 09-07-2025, on 87761, and 0.588, dated 09-07-2025, on 88761.

Both red tables print 500 ft, 1,000 ft, and 5,000 ft

As of November 3, 2026, 87761 rows are red: 87761 002500 at 500 ft, 87761 0021000 at 1,000 ft, and 87761 0025000 at 5,000 ft, with footnote C. 88761 rows are red: 88761 002100 at 100 ft, 88761 002500 at 500 ft, 88761 0021000 at 1,000 ft, and 88761 0025000 at 5,000 ft. 88761 has a 100 ft row. 87761's table does not. 8761's plenum-number cell names 88761, 87761, and 82761. The CM diameter and the 64 Ohm cell stay on the 8761 and 88761 page.

What to copy onto the cable line

  • Part: 87761 or 88761, from the sheet opened November 3, 2026.
  • Jacket: PVDF or FEP, both 0.014 in and 0.116 in.
  • Pair: 1 of 22 AWG 7x30, black and red, FEP insulation, 22 AWG drain.
  • Impedance: 42 Ohm. Current: 9 A at 30°C. Conductor DCR: 18.2 Ohm/1000ft.
  • Temperature: UL 150°C and operating -20°C to +150°C, on both sheets.
  • Flammability: FT6 on 87761, or FT4 on 88761.
  • Suitability: indoor and UV resistance, or indoor and outdoor.
  • Listing: 300 V (CMP) on both. Non-plenum number: 8761.

87761 or 88761 note

Name the CMP jacket. Diameter, 42 Ohm, and 9 A match on these two sheets.

This prepares a request. It does not send one.

Questions these sheets answer

Does PVDF change 0.116 in?

Both nominal diameters are 0.116 in (2.95 mm), as of November 3, 2026. Both jacket walls are 0.014 in (0.36 mm). The material cell is what changes.

Does 87761's suitability cell say outdoor?

87761's applications line includes outdoor and burial, as of November 3, 2026. The suitability cell says indoor and UV resistance. 88761's suitability cell says indoor and outdoor.

Which sheet prints FT6?

87761 prints FT6, as of November 3, 2026. 88761 prints FT4. Both print NFPA 262 and UL 910 (Plenum).

Sources

Jacket polymer, flammability, suitability, and the matching electrical cells are from the Belden 87761 and 88761 technical data sheets. The plenum-number cell that names both is from the Belden 8761 technical data sheet. All three were opened November 3, 2026.