Belden 82761 PVC at 2.8 A or 88761 FEP at 9 A
Use 82761 for the PVC CMP jacket at 0.118 in, 15 Ohm/1000ft, and 2.8 A at 25°C. Use 88761 for the FEP CMP jacket at 0.116 in, 18.2 Ohm/1000ft, and 9 A at 30°C. Both print 42 Ohm.
On this page
Use Belden 82761 when the one-pair CMP cable is the PVC jacket at 2.8 A. As of November 3, 2026, that sheet lists a nominal jacket diameter of 0.118 in (3.00 mm), conductor DCR of 15 Ohm/1000ft, 2.8 A per conductor at 25°C, and UL temperature 75°C. Use Belden 88761 when the CMP cable is the FEP jacket at 9 A. As of the same day, that sheet lists a nominal jacket diameter of 0.116 in (2.95 mm), conductor DCR of 18.2 Ohm/1000ft, 9 A per conductor at 30°C, and UL temperature 150°C. Both print 42 Ohm and name 8761 as the non-plenum number. The CM sheet at 64 Ohm is on the 8761 and 88761 page.
PVC at 0.118 in, or FEP at 0.116 in, both over FEP insulation
As of November 3, 2026, both titles say 2 conductor, 22 AWG stranded tinned copper, FEP insulation, overall shield, CMP. 82761's jacket word in the title is PVC. 88761's jacket word is FEP. The construction element on each is one pair of 22 AWG 7x30. Insulation on both is FEP, 0.007 in (0.18 mm), nominal insulation diameter 0.042 in (1.1 mm). 82761 colors are black and red, written with an ampersand. 88761 colors are black, red. The shield on both is a 100% bi-laminate tape with a 22 AWG (7x30) tinned-copper drain. 82761's jacket cell is PVC, 0.014 in (0.36 mm), nominal diameter 0.118 in (3.00 mm). 88761's jacket cell is FEP, 0.014 in (0.36 mm), nominal diameter 0.116 in (2.95 mm). The wall thickness matches. The material and the diameter do not.
| Item | 82761 | 88761 |
|---|---|---|
| Jacket | PVC, 0.118 in | FEP, 0.116 in |
| Impedance | 42 Ohm | 42 Ohm |
| Conductor DCR | 15 Ohm/1000ft | 18.2 Ohm/1000ft |
| Shield DCR | 18.2 Ohm/1000ft | 12.86 Ohm/1000ft |
| Current | 2.8 A at 25°C | 9 A at 30°C |
| UL temperature | 75°C | 150°C |
| Operating range | -20°C to +75°C | -20°C to +150°C |
| Non-plenum number | 8761 | 8761 |
The 18.2 Ohm/1000ft cell is the shield on 82761 and the conductor on 88761
As of November 3, 2026, 82761 lists conductor DCR of 15 Ohm/1000ft and outer-shield DCR of 18.2 Ohm/1000ft (59.7 Ohm/km). Capacitance is 35 pF/ft (110 pF/m) and 67 pF/ft (220 pF/m). Inductance is 0.16 µH/ft (0.52 µH/m). Impedance is 42 Ohm. Current is 2.8 A per conductor at 25°C. 88761 lists conductor DCR of 18.2 Ohm/1000ft and outer-shield DCR of 12.86 Ohm/1000ft (42.19 Ohm/km). Capacitance and inductance match the 82761 pair of cells. Impedance is 42 Ohm. Current is 9 A per conductor at 30°C. The current cells use different temperatures. Voltage on both is 300 V (CMP). NEC / UL compliance is Article 800, CMP. CEC compliance is CMP. Neither sheet prints AWM 2092, which stays on 8761.
Indoor plenum on 82761, indoor and outdoor on 88761
As of November 3, 2026, 82761's applications line says indoor plenum, plus low-voltage analog, digital, line-level audio, voice, and panel wiring. Suitability is indoor plenum and indoor. UL temperature is 75°C. Operating temperature is -20°C to +75°C. Flammability is NFPA 262, UL 910 (Plenum), and FT6. That flammability cell does not print IEC 60332-1-2. Bend radius is 1.18 in (30.0 mm). Pull tension is 27 lbs (12 kg). Bulk weight is 11 lbs/1000ft. 88761's applications line adds extreme high and low temperature, chemical resistance, outdoor, and burial. Suitability is indoor and outdoor. UL temperature is 150°C. Operating temperature is -20°C to +150°C. Flammability is NFPA 262, UL 910 (Plenum), FT4, and IEC 60332-1-2. Bend radius is 1.2 in (30 mm). Pull tension is 27.3 lbs (12.4 kg). Bulk weight is 13 lbs/1000ft. Page revision is 0.551, dated 09-07-2025, on 82761, and 0.588, dated 09-07-2025, on 88761.
Natural lengths on 82761, red lengths on 88761
As of November 3, 2026, 82761 variant rows are natural and print a length: 82761 877U500 at 500 ft, 82761 8771000 at 1,000 ft with footnote C, and 82761 8775000 at 5,000 ft. 88761 variant rows are red: 88761 002100 at 100 ft, 88761 002500 at 500 ft, 88761 0021000 at 1,000 ft, and 88761 0025000 at 5,000 ft. 8761's plenum-number cell also names 87761. That PVDF sheet shares 88761's 9 A cell and is on the 87761 and 88761 page.
What to copy onto the cable line
- Part: 82761 or 88761, from the sheet opened November 3, 2026.
- Non-plenum number: 8761, on both sheets.
- Jacket: PVC at 0.118 in, or FEP at 0.116 in. Insulation is FEP on both.
- Impedance: 42 Ohm on both.
- Conductor DCR: 15 Ohm/1000ft, or 18.2 Ohm/1000ft.
- Shield DCR: 18.2 Ohm/1000ft on 82761, or 12.86 Ohm/1000ft on 88761.
- Current: 2.8 A at 25°C, or 9 A at 30°C.
- Temperature: UL 75°C and operating -20°C to +75°C, or UL 150°C and operating -20°C to +150°C.
Questions these sheets answer
Which 18.2 Ohm/1000ft cell is the conductor?
On 82761, 18.2 Ohm/1000ft is the outer-shield DCR, as of November 3, 2026. The conductor cell is 15 Ohm/1000ft. On 88761, 18.2 Ohm/1000ft is the conductor DCR.
Does 42 Ohm mean 9 A?
Both sheets print 42 Ohm, as of November 3, 2026. 82761 prints 2.8 A at 25°C. 88761 prints 9 A at 30°C. The Ohm cell does not pick the current.
Which flammability cell prints IEC 60332-1-2?
88761 prints IEC 60332-1-2 with FT4, as of November 3, 2026. 82761 prints NFPA 262, UL 910, and FT6, and does not print that IEC line.
Sources
Jacket, DCR, current, and temperature are from the Belden 82761 and 88761 technical data sheets. The plenum-number cell that names both is from the Belden 8761 technical data sheet. All three were opened November 3, 2026.