Skip to the guide

Industrial networking

Belden 7962A TPE or 7960A PVC for a PROFINET Quad

Use 7962A for 22 AWG 19x34 tinned copper, a TPE jacket at 0.276 in, and the 1 million cycle note. Use 7960A for 22 AWG solid bare copper, a PVC jacket at 0.265 in, and CMG.

Rust Belt Industrials · November 5, 2026 · 5 min read

On this page

Use Belden 7962A when the PROFINET quad is the TPE jacket with a flex-life note. As of November 5, 2026, that sheet lists 22 AWG 19x34 tinned copper, a TPE jacket of 0.276 in (7.01 mm), UL temperature 75°C, and a table note of C-track flex life, 1 million cycles on a 3-inch radius. Use Belden 7960A when the PROFINET quad is the PVC jacket on solid bare copper. As of the same day, that sheet lists 22 AWG solid bare copper, a PVC jacket of 0.265 in (6.73 mm), UL temperature 60°C, and 300 V (CMG, CMX-Outdoor). 7962A's voltage cell is 300 V (CM, CMX-Outdoor) and 600 V (AWM 20626). 7960A also lists 600 V (AWM 21047). Both suitable-application cells start with PROFINET. Neither sheet names the other part number. A Type A or Type C Siemens cable is a different construction, on the 6XV1840-2AH10 and 6XV1840-3AH10 page.

One quad, green, with a different conductor and a different jacket

As of November 5, 2026, both sheets are DataTuff Category 5e, one quad of two pairs, polyolefin insulation, colors white, blue, yellow, and orange. Both have a polyethylene inner jacket and an overall Beldfoil tape at 100% plus a tinned-copper braid at 85%. 7962A's conductor is 22 AWG 19x34 tinned copper. The inner jacket is 0.169 in (4.29 mm). The outer jacket is TPE, 0.276 in (7.01 mm), with no ripcord. 7960A's conductor is 22 AWG solid bare copper. The inner jacket is 0.164 in (4.17 mm). The outer jacket is PVC, 0.265 in (6.73 mm), with no ripcord. Suitable applications on both continue past PROFINET into outdoor, harsh environment, IIoT, factory or process automation, IP cameras and devices, and data communication. The sheets do not print a cross-reference cell.

7962A and 7960A rows from the technical data sheets opened November 5, 2026.
Item7962A7960A
Conductor22 AWG 19x34 tinned22 AWG solid bare
JacketTPE, 0.276 inPVC, 0.265 in
Inner jacketPE, 0.169 inPE, 0.164 in
UL temperature75°C60°C
Voltage cell300 V (CM, CMX-Outdoor)300 V (CMG, CMX-Outdoor)
AWM600 V, AWM 20626600 V, AWM 21047
Flex-life note1 million cycles, 3-inch radiusNo flex-life line
IEC lineIEC 61156-6IEC 61156-5

17 Ohm/1000ft matches, and the 100 MHz loss does not

As of November 5, 2026, both sheets list maximum conductor DCR of 57 Ohm/km (17 Ohm/1000ft) and maximum capacitance unbalance of 150 pF/ft. Maximum delay is 552 ns/100m. Nominal velocity is 70%. Neither electrical block prints a single characteristic-impedance cell. The high-frequency table prints unfitted impedance of 100 plus or minus 20.2 Ohm at 1 MHz and 100 plus or minus 20.0 Ohm at 100 MHz, on both sheets. Fitted impedance at 1 MHz is 105 plus or minus 10 Ohm on both. Insertion loss at 1 MHz is 2.6 dB/100m on 7962A and 2.1 dB/100m on 7960A. Insertion loss at 100 MHz is 25.6 dB/100m on 7962A and 21.3 dB/100m on 7960A. The notes say limits below 4 MHz are for information only. 7962A's voltage cell is 300 V (CM, CMX-Outdoor) and 600 V (AWM 20626). NEC / UL compliance is Article 800, CM, CMX-Outdoor, ITC, PLTC. 7960A's voltage cell is 300 V (CMG, CMX-Outdoor) and 600 V (AWM 21047). NEC / UL compliance is Article 800, CMG, CMX-Outdoor, ITC, PLTC. CEC compliance is CMX-Outdoor on 7962A and CMX-Outdoor; CMG on 7960A.

The flex-life note is only on 7962A

As of November 5, 2026, 7962A lists UL temperature 75°C, operating temperature -40°C to +80°C, installation -20°C to +60°C, and storage -40°C to +80°C. A table note under temperature says flex life: C-track, 1 million cycles on a 3-inch radius. Stationary bend radius is 2.560 in (65.02 mm). Pull tension is 55 lbs (25 kg). Bulk weight is 45 lbs/1000ft (67 kg/km). Suitability is indoor, outdoor, sunlight resistance, and oil resistance. Flammability is UL 1685 (UL Loading), FT4, and IEEE 1202. The standards block that was read does not include a CPR line. ISO/IEC compliance is ISO/IEC 11801-1, IEC 61156-6. 7960A lists UL temperature 60°C, the same operating and storage spans, and installation -25°C to +60°C. It does not print the flex-life note. Stationary bend radius and pull tension match 7962A. Bulk weight is 41 lbs/1000ft. Flammability matches, and CPR is Euroclass Eca. ISO/IEC compliance is ISO/IEC 11801-1, IEC 61156-5. Both print NEMA WC-63.1, ANSI/TIA-568.2-D Category 5e, and a note that operating temperature is subject to length de-rating and that the cable passes a -40C cold bend per UL 1581. Page revision is 0.582, dated 06-11-2026, on 7962A, and 0.429, dated 02-20-2026, on 7960A.

Green RAL 6018 on both

As of November 5, 2026, both sheets list metric reels and RAL 6018 rows. 7962A lists 7962A.00305 green at 305 m, 7962A.00610 green at 610 m, and 7962A 1SW1000 and 7962A 1SW2000 in green, RAL 6018, without a length in those two rows. 7960A lists 7960A.00305 green at 305 m, 7960A.00610 green at 610 m, and 7960A 1SW1000 and 7960A 1SW2000 in green, RAL 6018, also without a length in those two rows. Jacket compound still comes from the material cell, TPE or PVC.

What to copy onto the cable line

  • Part: 7962A or 7960A, from the sheet opened November 5, 2026.
  • Quad: 22 AWG 19x34 tinned, or 22 AWG solid bare. Colors white, blue, yellow, orange.
  • Jacket: TPE at 0.276 in, or PVC at 0.265 in.
  • Inner jacket: PE at 0.169 in, or PE at 0.164 in. Braid coverage: 85% on both.
  • Voltage: 300 V (CM, CMX-Outdoor) and AWM 20626, or 300 V (CMG, CMX-Outdoor) and AWM 21047.
  • UL temperature: 75°C, or 60°C. Operating range on both: -40°C to +80°C.
  • Flex life: 1 million C-track cycles on a 3-inch radius, on 7962A. 7960A does not print that note.
  • IEC line: IEC 61156-6, or IEC 61156-5.

7962A or 7960A note

Name the PROFINET quad. The flex-life note is on 7962A. The CMG cell is on 7960A.

This prepares a request. It does not send one.

Questions these sheets answer

Does the TPE sheet print CMG?

7962A's voltage cell is 300 V (CM, CMX-Outdoor), as of November 5, 2026. NEC compliance lists CM, not CMG. 7960A's voltage cell is 300 V (CMG, CMX-Outdoor), and the NEC line includes CMG.

Which sheet prints 1 million cycles?

7962A's temperature table note says C-track flex life, 1 million cycles on a 3-inch radius, as of November 5, 2026. 7960A does not print that note. Stationary bend radius is 2.560 in on both.

Does stranding change the 17 Ohm/1000ft cell?

Both conductor-DCR cells print 57 Ohm/km (17 Ohm/1000ft), as of November 5, 2026. The conductor construction is still 19x34 tinned on 7962A and solid bare on 7960A.

Sources

Conductor, jacket, voltage, temperature, and the flex-life note are from the Belden 7962A and 7960A technical data sheets. Both were opened November 5, 2026. Both suitable-application cells start with PROFINET. Neither sheet names the other part number.