Belden 7921A Shielded 24 AWG or 7922A 22 AWG Cat 5e

Use 7921A for the shielded 24 AWG Cat 5e at 0.33 in and CMR. Use 7922A for the 22 AWG Cat 5e at 0.301 in with PLTC and AWM 21047. Both are 4 bonded pairs.

Rust Belt Industrials · October 29, 2026 · 6 min read

On this page

Use Belden 7921A when the industrial Cat 5e cable is the shielded 24 AWG construction. As of October 29, 2026, that sheet lists four bonded pairs, an overall foil and a 70% tinned-copper braid, a PVC jacket of 0.33 in (8.4 mm), and 300 V ratings of CMR and CMX-Outdoor. Use Belden 7922A when the cable is the 22 AWG construction with a tray listing. As of the same day, that sheet lists four bonded pairs, a PVC jacket of 0.301 in (7.65 mm), 300 V (PLTC, CMR/CMX-Outdoor), and 600 V (AWM). 7922A's description and construction do not print a shield. Both data-category cells say Category 5e. A PROFINET type choice is a different cable family, on the PROFINET and Ethernet page.

Both titles say industrial Ethernet Cat 5e, and the shield is on 7921A

As of October 29, 2026, 7921A's description is industrial Ethernet Cat 5e, 4 bonded-pair 24 AWG solid bare copper, polyolefin insulation, overall Beldfoil and tinned-copper braid at 70%, PVC jacket, CMR CMX-Outdoor. Suitable applications name a noisy environment, outdoor, harsh environment, IIoT, factory or process automation, IP cameras and devices, and data communication. 7922A's description is industrial Ethernet Cat 5e, 4 bonded-pair 22 AWG solid bare copper, polyolefin insulation, PVC jacket, PLTC CMR/CMX-Outdoor. Suitable applications name power-limited tray, harsh environment, IIoT, factory or process automation, IP cameras and devices, and data communication. The shared Cat 5e title and the shared camera and factory lines are why these two part numbers are alternatives. The shield and the tray listing pick which sheet to copy. 7921A's shield is a 100% bi-laminate tape with two 26 AWG solid tinned-copper drains applied helically, plus a 70% tinned-copper braid. 7922A has no shield block.

24 AWG at 0.33 in, or 22 AWG at 0.301 in, both bonded pairs

As of October 29, 2026, both sheets list solid bare copper and polyolefin insulation. Pair colors on both are white/blue stripe and blue, white/orange stripe and orange, white/green stripe and green, and white/brown stripe and brown. Both print Bonded-Pair: Yes. 7921A's conductor is 24 AWG. The product title says 4 bonded pairs. The jacket is PVC, nominal diameter 0.33 in (8.4 mm), and the ripcord cell says No. 7922A's conductor cell says 22 AWG and 4 pairs. The jacket is PVC, nominal diameter 0.301 in (7.65 mm), and the ripcord cell says Yes. Neither jacket cell prints a thickness.

7921A and 7922A rows from the technical data sheets opened October 29, 2026.
Item7921A7922A
Conductor24 AWG solid bare copper22 AWG solid bare copper
ShieldFoil and 70% braidNo shield block on the sheet
JacketPVC, 0.33 inPVC, 0.301 in
1 MHz impedance100 ± 15 Ohm, unfitted100 ± 12 Ohm, unfitted
Max conductor DCR93.8 Ohm/km (28.6 Ohm/1000ft)56.5 Ohm/km (17.2 Ohm/1000ft)
Operating range-40°C to +75°C-25°C to +75°C
Voltage300 V CMR and 300 V CMX-Outdoor300 V PLTC, CMR/CMX-Outdoor, and 600 V AWM
ListingArticle 800, CMR, CMX-OutdoorArticle 800, Article 725, PLTC, CMR, CMX-Outdoor

Category 5e on both, with the 1 MHz impedance taken from the filled cells

As of October 29, 2026, both data-category cells say Category 5e. Both name ANSI/TIA-568.2-D Category 5e, a third-party performance line of Category 5e, and ISO/IEC 11801-1 and IEC 61156-5. Maximum conductor DCR is 93.8 Ohm/km (28.6 Ohm/1000ft) on 7921A and 56.5 Ohm/km (17.2 Ohm/1000ft) on 7922A. Those cells are labeled max, and the sheets do not print a separate nominal DCR. Capacitance unbalance is 150 pF/ft on 7921A and 66 pF/100m on 7922A. The units are the units in the cells. Maximum delay is 538 ns/100m on 7921A and 510 ns/100m on 7922A. Maximum delay skew is 45 ns/100m on 7921A and 25 ns/100m on 7922A. Nominal velocity is 70% on both. At 1 MHz, 7921A's unfitted input impedance is 100 ± 15 Ohm and the fitted impedance is 95-110 Ohm. At 1 MHz, 7922A's unfitted input impedance is 100 ± 12 Ohm and the fitted impedance is 105 ± 10 Ohm. The 100 MHz input-impedance cells are empty on both sheets. Maximum insertion loss at 100 MHz is 22.0 dB/100m on 7921A and 21.7 dB/100m on 7922A.

CMR and CMX-Outdoor on 7921A, plus PLTC and AWM 21047 on 7922A

As of October 29, 2026, 7921A's UL voltage rating is 300 V (CMR) and 300 V (CMX-Outdoor). NEC / UL compliance is Article 800, CMR, CMX-Outdoor. CEC / C(UL) compliance is CMX-Outdoor. UL temperature is 60°C. Operating temperature is -40°C to +75°C. Installation is -25°C to +75°C. Storage is -40°C to +80°C. The notes say operating temperatures are subject to length de-rating, and that the cable passes -40C Cold Bend per UL 1581. The sheet does not print a de-rating table. Stationary bend radius is 1.32 in (33.5 mm). Pull tension is 75 lbs (34 kg). Weight is 50 lbs/1000ft. Suitability is indoor/outdoor, indoor, outdoor, sunlight resistance, and oil resistance. Flammability is UL 1666 Riser, FT4, IEEE 1202 vertical tray, and IEC 60332-1-2. 7922A's UL voltage rating is 300 V (PLTC, CMR/CMX-Outdoor) and 600 V (AWM). AWM compliance is AWM 21047. NEC / UL compliance is Article 800, Article 725, CMR, CMX-Outdoor, PLTC. CEC / C(UL) compliance is CMR. UL temperature is 60°C. Operating temperature is -25°C to +75°C. Installation is -10°C to +75°C. Storage is -25°C to +75°C. The notes say operating temperatures are subject to length de-rating and do not print a cold-bend line. Stationary bend radius is 1.2 in (30 mm). Pull tension is 40 lbs (18 kg). Weight is 42 lbs/1000ft. Flammability is UL 1666 Riser, FT4, and IEC 60332-1-2. It does not print IEEE 1202. Both CPR cells include Euroclass Eca. 7921A also prints UKCA Class Eca. Page revision is 0.536 on 7921A and 0.657 on 7922A, both dated 02-20-2026.

What to copy onto the cable line

  • Part: 7921A or 7922A, from the sheet opened October 29, 2026.
  • Pairs: 4 bonded pairs, 24 AWG shielded, or 22 AWG with no shield block.
  • Jacket: PVC at 0.33 in, or PVC at 0.301 in.
  • Category: Category 5e on both, including ANSI/TIA-568.2-D.
  • 1 MHz impedance: 100 ± 15 Ohm unfitted, or 100 ± 12 Ohm unfitted.
  • DCR: 93.8 Ohm/km, or 56.5 Ohm/km. Both cells are maximums.
  • Voltage: 300 V CMR and 300 V CMX-Outdoor, or 300 V PLTC plus 600 V AWM 21047.
  • Operating range: -40°C to +75°C, or -25°C to +75°C. The de-rating note has no table.

7921A or 7922A note

Name the Cat 5e part and copy the gauge, shield, and voltage from that sheet.

This prepares a request. It does not send one.

Questions these sheets answer

Does 7922A print a braid?

7921A prints an overall foil and a 70% tinned-copper braid, as of October 29, 2026. 7922A's description and construction do not print a shield.

Which 1 MHz cell is 100 ± 15 Ohm?

7921A's unfitted input impedance at 1 MHz is 100 ± 15 Ohm, as of October 29, 2026. 7922A's unfitted cell at 1 MHz is 100 ± 12 Ohm. The 100 MHz impedance cells are empty on both sheets.

Does 7922A keep the -40°C operating low?

7921A's operating range is -40°C to +75°C, as of October 29, 2026. 7922A's operating range is -25°C to +75°C. The -40C cold-bend note is on 7921A and is not an operating cell.

Sources