Belden 3092A Solid or 3092F High Flex
Use 3092A for the 18 AWG solid coax at 162 lbs pull. Use 3092F for the 20 AWG high-flex coax at 35 lbs pull. Both list 75 Ohm and 0.303 in.
On this page
Use Belden 3092A when the Modbus II coax is the standard quad-shield row: 18 AWG solid bare copper covered steel, 75 Ohm, and a PVC jacket of 0.303 in (7.70 mm). As of October 25, 2026, maximum pull tension on that page is 162 lbs (73.5 kg). Use Belden 3092F when the category high-flex link is the row: 20 AWG (105x40) bare copper, 75 Ohm, and the same 0.303 in (7.70 mm) jacket. As of the same day, maximum pull tension on 3092F is 35 lbs (16 kg), and the notes print a flex life of 1.5 million cycles at a 6.0 in minimum bend radius. Armor is a third part, on the 123092A page.
The category page separates standard and high flex
Belden's Modbus category page, opened October 25, 2026, links 3092A from the Modbus II row described as standard quad shield coax, 18 AWG, 1 coax. The next line, high flex, links 3092F. Both product pages name Modbus II and ControlNet in the suitable-applications cell. 3092A's title is the standard RG-6 quad-shield construction. 3092F's title adds high flex and CMR. A request that says only Modbus II and 75 Ohm has not chosen the conductor.
Solid steel-covered copper, or stranded bare copper
As of October 25, 2026, 3092A's conductor is 18 AWG solid bare copper covered steel, nominal diameter 0.040 in. Insulation is foam polyethylene, white, nominal insulation diameter 0.180 in (4.57 mm). 3092F's conductor is 20 AWG, 105x40, bare copper, nominal diameter 0.040 in. Insulation is foam polyethylene, white, nominal insulation diameter 0.183 in (4.65 mm). The shield stack matches: Duobond II tape at 100%, aluminum braid at 60%, Duofoil tape at 100%, and aluminum braid at 40%. Both PVC jackets are 0.303 in (7.70 mm), and that figure is also the overall diameter on both pages.
Part-number rows on 3092A, as of October 25, 2026, include black reels and blue X7E reels. 3092F rows are black reels at 1,000 ft and 5,000 ft. 3092A's plenum-number cell is 3093A. The 3092F page has no plenum-number cell. High-temp impedance, 75 Ohm or 100 Ohm, is on the 3093A and 3132A page.
| Item | 3092A | 3092F |
|---|---|---|
| Conductor | 18 AWG, solid, bare copper covered steel | 20 AWG, 105x40, bare copper |
| Impedance | 75 Ohm | 75 Ohm |
| Conductor DCR | 28 Ohm/1000ft | 10.5 Ohm/1000ft |
| Velocity | 83% | 82% |
| Nominal OD | 0.303 in (7.70 mm) | 0.303 in (7.70 mm) |
| Operating range | -30°C to +75°C | -40°C to +75°C |
| Max pull tension | 162 lbs (73.5 kg) | 35 lbs (16 kg) |
| Flex-life note | None on this page | 1.5 million cycles at 6.0 in |
75 Ohm on both, with a different loss table
As of October 25, 2026, 3092A lists conductor DCR of 28 Ohm/1000ft, outer-shield DCR of 2.6 Ohm/1000ft (8.5 Ohm/km), capacitance of 16.2 pF/ft (53.1 pF/m), impedance of 75 Ohm, and velocity of 83%. Minimum structural return loss is 23 dB from 5 MHz to 50 MHz. Nominal attenuation is 0.35 dB/100ft at 1 MHz, 0.59 dB/100ft at 10 MHz, and 1.97 dB/100ft at 100 MHz. UL voltage is 300 V (CMR, CMG). There is no ampacity cell.
As of October 25, 2026, 3092F lists conductor DCR of 10.5 Ohm/1000ft, outer-shield DCR of 2.6 Ohm/1000ft (8.5 Ohm/km), capacitance of 16.3 pF/ft (53.5 pF/m), impedance of 75 Ohm, and velocity of 82%. Minimum structural return loss is 23 dB from 5 MHz to 400 MHz. Nominal attenuation is 0.36 dB/100ft at 1 MHz, 1.2 dB/100ft at 10 MHz, and 4.6 dB/100ft at 100 MHz, and the table continues through 9.3 dB/100ft at 400 MHz. UL voltage is 300 V (CMR, CMG). An electrical note names IEEE 802.4 MAP and IEEE 802.7 Mini-Map. That note is on 3092F. It is not on the 3092A electrical table.
Pull tension, bend, and the flex-life note
As of October 25, 2026, 3092A lists UL temperature 75°C and operating temperature -30°C to +75°C. The bend table prints an installation minimum of 3 in (76 mm) and no stationary cell. Weight is 33 lbs/1000ft. Environmental suitability is indoor/outdoor, indoor, outdoor, sunlight resistance, and aerial when supported by messenger wire. Flammability is UL 1666 vertical shaft. NEC compliance is CMR, CL2R, and CMG. Page revision is 0.602, dated 02-20-2026.
As of October 25, 2026, 3092F lists UL temperature 75°C and operating temperature -40°C to +75°C. Installation bend minimum is 3 in (76 mm). Weight is 29 lbs/1000ft. Environmental suitability is indoor riser, indoor, and aerial when supported by messenger wire. Flammability is UL 1666 riser. CPR is Euroclass Eca. NEC compliance is CMR and CL2R. CEC compliance is CMG. The notes print flex life of 1.5 million cycles at a 6.0 in minimum bend radius. The same notes name Rockwell authorized flexible ControlNet order YR28890 as a tinned-copper braid version. That page was not opened, so its ratings stay off this comparison. Page revision is 0.511, dated 02-20-2026. The 3-pair drop at 50 Ohm is on the 8777 and 3092A page.
What to copy onto the cable line
- Row: standard Modbus II coax, or the high-flex line, from the category page opened October 25, 2026.
- Part: 3092A or 3092F.
- Conductor: 18 AWG solid bare copper covered steel, or 20 AWG 105x40 bare copper.
- Impedance: 75 Ohm on the part you named.
- Pull tension: 162 lbs (73.5 kg), or 35 lbs (16 kg).
- Flex life, when the part is 3092F: 1.5 million cycles at 6.0 in.
Questions these two pages answer
Does 0.303 in pick the flex cable?
Both overall diameters are 0.303 in (7.70 mm), as of October 25, 2026. The conductor, the pull tension, and the flex-life note pick 3092F. 3092A has no flex-life sentence.
Which DCR goes with 20 AWG?
10.5 Ohm/1000ft is the conductor DCR on 3092F, as of October 25, 2026. 28 Ohm/1000ft is the conductor DCR on 3092A. Outer-shield DCR is 2.6 Ohm/1000ft (8.5 Ohm/km) on both pages.
Is YR28890 the same rating block as 3092F?
The 3092F notes name YR28890 as a tinned-copper braid version. That product page was not opened on October 25, 2026. Pull tension, flex life, and 75 Ohm on this page are the 3092F cells.
Sources
Conductor, impedance, attenuation, pull tension, and the flex-life note are from the Belden 3092A and 3092F pages. The standard and high-flex links are from the Belden Modbus category page. All three were opened October 25, 2026. YR28890 was not opened.