Industrial networking
Belden 3092A Unarmored or 123092A Aluminum Armor
Use 3092A for the unarmored coax at 0.303 in. Use 123092A for aluminum interlock armor at 0.591 in. Both list 75 Ohm.
On this page
Use Belden 3092A when the Modbus II coax is unarmored: 75 Ohm, PVC jacket, overall diameter 0.303 in (7.70 mm), operating -30°C to +75°C, as of October 25, 2026. Use Belden 123092A when the category aluminum-armor link is the row: 75 Ohm, aluminum interlock armor, overall diameter 0.591 in (15.0 mm), operating -40°C to +75°C. Maximum pull tension is 162 lbs (73.5 kg) on 3092A and 200 lbs (91 kg) on 123092A. The steel-armor cell on the category table is empty. High flex is a different conductor, on the 3092F page.
Aluminum armor has a product link, and steel armor does not
The Modbus category page opened October 25, 2026 links 3092A as the standard Modbus II coax and 123092A as the aluminum-armor line under that system. The steel-armor cell on the same Modbus II block is blank. A request for steel armor has no product number on that cell. Both product pages name Modbus II. 123092A's suitable-applications cell also names exposure to rodent, crush, or cut-through force.
The armor sits outside an inner PVC jacket
As of October 25, 2026, 3092A is one 18 AWG solid bare-copper-covered-steel conductor, nominal diameter 0.040 in, foam polyethylene insulation at 0.180 in (4.57 mm), and a four-layer shield that starts with Duobond II. The PVC jacket is the outside of the cable at 0.303 in (7.70 mm).
As of October 25, 2026, 123092A is one 18 AWG solid bare-copper-covered-steel conductor, nominal diameter 0.0403 in, foam polyethylene insulation at 0.178 in (4.52 mm). The shield starts with Duofoil at 100%, then an aluminum braid at 60%, Duofoil at 100%, and an aluminum braid at 40%. An inner PVC jacket is 0.298 in (7.57 mm). Armor is aluminum interlock, 0.025 in (0.64 mm) thick, with a diameter over armor of 0.501 in (12.7 mm). The outer PVC jacket and the overall diameter are both 0.591 in (15.0 mm).
| Item | 3092A | 123092A |
|---|---|---|
| Armor | None. The PVC jacket is the outside. | Aluminum interlock, 0.025 in (0.64 mm) |
| Overall diameter | 0.303 in (7.70 mm) | 0.591 in (15.0 mm) |
| Impedance | 75 Ohm | 75 Ohm |
| Outer-shield DCR | 2.6 Ohm/1000ft (8.5 Ohm/km) | 3.6 Ohm/1000ft (12 Ohm/km) |
| UL voltage | 300 V (CMR, CMG) | 300 V |
| Operating range | -30°C to +75°C | -40°C to +75°C |
| Max pull tension | 162 lbs (73.5 kg) | 200 lbs (91 kg) |
| Weight | 33 lbs/1000ft | 142 lbs/1000ft |
75 Ohm, and attenuation that matches at the printed frequencies
As of October 25, 2026, both pages list 75 Ohm and capacitance of 16.2 pF/ft (53.1 pF/m) conductor to shield. 3092A conductor DCR is 28 Ohm/1000ft. 123092A conductor DCR is 28 Ohm/1000ft (92 Ohm/km). Outer-shield DCR is 2.6 Ohm/1000ft (8.5 Ohm/km) on 3092A and 3.6 Ohm/1000ft (12 Ohm/km) on 123092A. Velocity is 83% on 3092A and 82% on 123092A. Minimum structural return loss on both pages is 23 dB from 5 MHz to 50 MHz. 123092A also repeats that span in an electrical note.
Nominal attenuation on 123092A matches the 3092A table at each frequency the two pages both print, in dB/100ft: 0.35 at 1 MHz, 0.38 at 2 MHz, 0.45 at 5 MHz, 0.59 at 10 MHz, 0.86 at 20 MHz, 1.37 at 50 MHz, 1.97 at 100 MHz, 2.82 at 200 MHz, 3.48 at 300 MHz, and 4.04 at 400 MHz. The voltage cell on 3092A is 300 V (CMR, CMG). The voltage cell on 123092A is 300 V. Copy the label that sits on the part.
Bend, listing, and where the cable may be routed
As of October 25, 2026, 3092A lists an installation bend of 3 in (76 mm) and no stationary cell. Environmental suitability includes indoor, outdoor, and sunlight resistance, plus aerial on a messenger wire. Flammability is UL 1666 vertical shaft. NEC compliance is CMR, CL2R, and CMG. The plenum-number cell is 3093A. Page revision is 0.602, dated 02-20-2026.
As of October 25, 2026, 123092A lists a stationary bend of 4 in (100 mm) and an installation bend of 2.5 in (64 mm). UL temperature is 75°C. Environmental suitability is indoor (not riser or plenum), indoor, outdoor, and sunlight resistance. Flammability is UL 1685 UL Loading, FT4, and 1202. CPR is Euroclass Eca. NEC compliance is Article 800, CL2, and CM. CEC compliance is CMG and HL. Notes say ControlNet is a ControlNet International trademark. Page revision is 0.271, dated 10-08-2026. The 50 Ohm 3-pair drop is on the 8777 and 3092A page.
What to copy onto the cable line
- Armor: unarmored 3092A, or aluminum interlock on 123092A, from pages opened October 25, 2026.
- Overall diameter: 0.303 in (7.70 mm), or 0.591 in (15.0 mm).
- Armor thickness, when the part is 123092A: 0.025 in (0.64 mm), diameter over armor 0.501 in (12.7 mm).
- Impedance: 75 Ohm on the part you named.
- Operating range: -30°C to +75°C, or -40°C to +75°C.
- Pull tension: 162 lbs (73.5 kg), or 200 lbs (91 kg).
Questions these two pages answer
Which part number is in the steel-armor cell?
The steel-armor cell under Modbus II is empty on the category page opened October 25, 2026. 123092A is the aluminum-armor link. A steel-armor request needs a page that prints a part number.
Is 0.298 in the overall diameter?
0.298 in (7.57 mm) is the inner PVC jacket on 123092A, as of October 25, 2026. The overall diameter, outside the armor and the outer jacket, is 0.591 in (15.0 mm). 0.303 in (7.70 mm) is the overall diameter of unarmored 3092A.
Does armor change the attenuation table?
At the frequencies both pages print, from 1 MHz through 400 MHz, the nominal attenuation numbers match, as of October 25, 2026. Shield DCR, voltage label, bend, weight, and overall diameter do not match. Those cells stay with the part that prints them.
Sources
Diameter, armor, impedance, attenuation, voltage, and pull tension are from the Belden 3092A and 123092A pages. The aluminum-armor link and the empty steel-armor cell are from the Belden Modbus category page. All three were opened October 25, 2026.