Skip to the guide

Power connections

Telecommunications Main Grounding Busbar or TGB

Use the 4 inch Panduit main busbar for the telecommunications main grounding busbar. Use the 2 inch Panduit bar for the TGB. An nVent TMGB is also 4 inch by 1/4 inch copper.

Rust Belt Industrials · November 8, 2026 · 7 min read

On this page

Use the 4 inch bar when the copper grounding busbar is the telecommunications main grounding busbar. As of November 8, 2026, Panduit's main-busbar block lists that bar at 4 in wide and 0.25 in thick, at 12 in (GB4B0612TPI-1), 20 in (GB4B0624TPI-1), and 24 in (GB4B1028TPI-1). Use the 2 inch bar when it is the telecommunications grounding busbar, the TGB. The same catalog lists that block at 2 in wide and 0.25 in thick, at 10 in (GB2B0304TPI-1), 12 in (GB2B0306TPI-1), 20 in (GB2B0312TPI-1), and 24 in (GB2B0514TPI-1). nVent TMGBA16L19P is a telecom main grounding busbar at 4 in wide and 1/4 in thick, with tin plating no and 19 pairs of 5/16 in holes. The 12 in by 4 in ERICO CC bar is a different catalog number, on the EGBA page.

Panduit prints the main bar at 4 inches and the TGB at 2 inches

The Electrical Infrastructure catalog opened November 8, 2026 titles one block StructuredGround Telecommunications Main Grounding Busbar and the next block StructuredGround Telecommunications Grounding Busbar. The main block prints width 4 in (101.6 mm) and thickness 0.25 in (6.4 mm). Lengths in that block are 12 in (304.8 mm) for GB4B0612TPI-1, 20 in (508 mm) for GB4B0624TPI-1, and 24 in (609.6 mm) for GB4B1028TPI-1. The block prints a stud hole of 7/16 in (11.2 mm). The GB4B1028TPI-1 line also prints a stud hole of 5/16 in (7.9 mm). The TGB block prints width 2 in (50.8 mm) and thickness 0.25 in (6.4 mm). Lengths are 10 in (254 mm) for GB2B0304TPI-1, 12 in (304.8 mm) for GB2B0306TPI-1, 20 in (508 mm) for GB2B0312TPI-1, and 24 in (609.6 mm) for GB2B0514TPI-1. The 20 in line prints a stud hole of 5/16 in. The 24 in line prints a stud hole of 7/16 in. The block also prints a stud hole of 7/16 in with the width and thickness.

The July 2013 StructuredGround sheet, opened November 8, 2026, is the second Panduit page for the room bar. Step 4 is titled bond the rack or cabinet to the Telecommunications Grounding Busbar (TGB). The part line for a small room is GB2B0306TPI-1, described as TGB, 1/4 in by 2 in by 12 in, quantity one per room. That description matches the catalog length, width, and thickness for GB2B0306TPI-1. The 2013 sheet does not print a stud-hole size, and it does not list the 4 in main busbar. A 12 in TGB request can copy 1/4 in by 2 in by 12 in from both Panduit pages. A main-busbar request copies the 4 in block from the catalog.

Panduit grounding busbar blocks opened November 8, 2026. Width and thickness are the cells printed in each block.
Role on the pageCatalog numberLengthWidthThickness
Telecommunications main grounding busbarGB4B0612TPI-112 in4 in0.25 in
Telecommunications main grounding busbarGB4B0624TPI-120 in4 in0.25 in
Telecommunications main grounding busbarGB4B1028TPI-124 in4 in0.25 in
Telecommunications grounding busbarGB2B0304TPI-110 in2 in0.25 in
Telecommunications grounding busbarGB2B0306TPI-112 in2 in0.25 in
Telecommunications grounding busbarGB2B0312TPI-120 in2 in0.25 in
Telecommunications grounding busbarGB2B0514TPI-124 in2 in0.25 in

nVent TMGBA16L19P is a 4 inch by 1/4 inch main bar

The nVent ERICO product sheet for catalog number TMGBA16L19P, opened November 8, 2026, titles the part Telecom Main Grounding Busbar, 15 1/2 in. It says the bar meets TIA-607-C and TIA-607-D, conforms to BICSI recommendations, and complies with NEMA standards. It accepts two-hole lugs with 5/16 in or 7/16 in bolt holes, and hardware is not included. Material is copper. Tin plating is no. Width is 4 in. Thickness is 1/4 in. Length L1 is 15 1/2 in. Length L2 is 9 in. Hole size 1 is 5/16 in, with 19 pairs. Hole size 2 is 7/16 in, with 3 pairs. Spacing A is 1 in, B is 1 1/8 in, C is 5/8 in, and D is 5/8 in.

The nVent grounding-busbar catalog page opened the same day prints more TMGB rows and a tin-plating heading. Above the heading Tin Plating: Yes, the page prints TMGBA20L27P at L1 20 in and L2 9 in, with 27 pairs of 5/16 in holes and 3 pairs of 7/16 in holes. TMGBA24L33P is 24 in and 18 in, with 33 and 5 pairs. TMGBA29L41P is 29 in and 18 in, with 41 and 5 pairs. Under Tin Plating: Yes, TMGBA12L15PT is 12 in and 9 in, with 15 and 3 pairs. TMGBA16L19PT is 15 1/2 in and 9 in, with 19 and 3 pairs. TMGBA18L23PT is 17 3/4 in and 9 in, with 23 and 3 pairs. TMGBA20L27PT, TMGBA24L33PT, and TMGBA29L41PT repeat the lengths and pair counts of the three rows above the heading, with the T on the catalog number. On these rows, A is 1 in, B is 1 1/8 in, C is 5/8 in, and D is 5/8 in. The catalog page does not print a width for those rows. The 4 in width and the tin-plating no line are on the TMGBA16L19P sheet.

The splice kit names a TGB series and a TMGB series

The nVent grounding-busbar catalog page opened November 8, 2026 prints a telecom grounding busbar splice kit. Material is copper and the finish is tinned. The kit includes two tinned copper splice plates and 1/4 in stainless steel fasteners. TGBSPLICEKIT is for the TGB series, height 2 in, width 3 in, thickness 1/4 in, hole size 11/32 in. TMGBSPLICEKIT is for the TMGB series, height 4 in, width 3 1/2 in, thickness 1/4 in, hole size 11/32 in. TMGBA16L19P is 4 in wide, and the TMGB splice-kit height is 4 in. The 2 in figure on TGBSPLICEKIT is the splice-kit height. The opened nVent pages do not print a TGB bar width. Panduit's 2 in width is the Panduit TGB block and the 2013 part line.

TMGBA12L15PT is the 12 in row under nVent's tin-plating heading, with 15 pairs of 5/16 in holes and 3 pairs of 7/16 in holes, and L2 of 9 in. GB4B0612TPI-1 is the 12 in row in Panduit's main block, at 4 in wide. The Panduit catalog does not print pair counts for that number. EGBA14412CC is a 12 in by 4 in by 1/4 in bar with hole pattern CC. The three catalog numbers stay on their own pages. Copy the number whose hole pattern is the one on the drawing.

What to copy onto the bar line

  • Role: telecommunications main grounding busbar, or TGB, from the pages opened November 8, 2026.
  • Panduit main bar: GB4B0612TPI-1, GB4B0624TPI-1, or GB4B1028TPI-1, at 4 in by 0.25 in.
  • Panduit TGB: GB2B0304TPI-1, GB2B0306TPI-1, GB2B0312TPI-1, or GB2B0514TPI-1, at 2 in by 0.25 in.
  • GB2B0306TPI-1 also reads 1/4 in by 2 in by 12 in on the 2013 sheet, one per room.
  • nVent TMGBA16L19P: 4 in by 1/4 in, L1 15 1/2 in, L2 9 in, tin plating no, 19 pairs of 5/16 in holes and 3 pairs of 7/16 in holes.
  • Other nVent rows from the catalog page: L1, L2, and pair counts, and whether the row is under Tin Plating: Yes.
  • Standards on the TMGBA16L19P sheet: TIA-607-C and TIA-607-D.
  • Splice kit, when the run is extended: TGBSPLICEKIT or TMGBSPLICEKIT, with the height printed for that series.

TMGB or TGB note

Name the main bar or the TGB. Copy the catalog number, the width, and the length.

This prepares a request. It does not send one.

Questions these grounding-bar pages answer

Is every 12 inch by 4 inch bar a TMGB?

GB4B0612TPI-1 is the 12 in row in Panduit's 4 in main block, as of November 8, 2026. TMGBA12L15PT is the 12 in row under nVent's Tin Plating: Yes heading. EGBA14412CC is a 12 in by 4 in bar with hole pattern CC. The catalog numbers are different hole patterns.

Which nVent row says tin plating no?

TMGBA16L19P says tin plating no, as of November 8, 2026. TMGBA16L19PT is the 15 1/2 in row under the catalog page's Tin Plating: Yes heading. The pair counts on those two rows match: 19 pairs of 5/16 in holes and 3 pairs of 7/16 in holes.

Where is the 2 inch width printed?

Panduit's telecommunications grounding busbar block prints 2 in, and the 2013 sheet prints 1/4 in by 2 in by 12 in for GB2B0306TPI-1, as of November 8, 2026. The nVent TGB splice kit is 2 in high. That kit height is not a bar-width cell.

Sources

Panduit widths, thicknesses, and lengths are from the Electrical Infrastructure catalog. The 1/4 in by 2 in by 12 in TGB line is from the July 2013 StructuredGround sheet. The 4 in by 1/4 in size, tin plating no, and TIA-607-C and TIA-607-D are from the TMGBA16L19P product sheet. The other TMGB lengths, the tin-plating heading, and the splice-kit sizes are from the nVent grounding-busbar catalog page. All four were opened November 8, 2026.