Power connections
Mersen MHi-T Laminated Busbar at 105°C, 130°C, or 180°C
Use a traditional laminated busbar at the flyer's 105°C working limit. Use MHi-T130 at 130°C and MHi-T180 at 180°C.
On this page
Use a traditional Mersen laminated busbar when the working temperature stays at 105°C. Use MHi-T130 when the working temperature is 130°C. Use MHi-T180 when it is 180°C. As of November 7, 2026, the MHi-T flyer says traditional laminated bus bars are limited to a working temperature of 105°C, and the MHi-T lineup allows working temperatures up to 130°C and 180°C. The flyer lists three names: MHi-T105, MHi-T130, and MHi-T180. Its high-operating-temperature block prints -50°C to 180°C, up to a 200°C peak, and an insulation-film RTI of 220°C. Electrical breakdown on that flyer is greater than 8 kV. Film continuous-use temperatures, including Kapton at 400°C, are a different table on the insulation film page.
The flyer names three MHi-T ratings and a 105°C traditional limit
The flyer opened November 7, 2026, document FL-MHI-T-001 dated 02.22, says wide-bandgap modules such as SiC and GaN raise the heat in laminated busbar connectors. It says increased temperature on a standard laminated busbar may cause partial or complete breakdown of the bonding agent, so the insulation can lift and separate from the conductor and create a shock or short-circuit fault. The construction it names for the MHi-T bars is polyaramid dielectric insulation and a high-temperature adhesive. The sentence on limits says traditional laminated bus bars are limited to a working temperature of 105°C, while the MHi-T lineup allows increased working temperatures up to 130°C and 180°C. A features list says three solutions are available at 105°C, 130°C, and 180°C, named MHi-T105, MHi-T130, and MHi-T180.
MHi-T105 carries the same 105°C figure as the traditional limit, as of November 7, 2026. The flyer lists it as one of the three MHi-T names and describes the lineup's increased temperatures as up to 130°C and 180°C. Use MHi-T130 or MHi-T180 when the working temperature is above that 105°C traditional limit and matches 130°C or 180°C. Use MHi-T105 when the order names that MHi-T product at 105°C. The flyer does not print a current, a voltage class for the busbar, or a bar size. The design guide opened the same day repeats the 105°C traditional limit and the 130°C and 180°C lineup language in its MHi-T section.
| Name on the flyer | Temperature the flyer prints | What that line is |
|---|---|---|
| Traditional laminated busbar | Working temperature limited to 105°C | The limit stated for a standard laminated busbar |
| MHi-T105 | 105°C | One of the three named MHi-T solutions |
| MHi-T130 | 130°C | The increased working temperature up to 130°C |
| MHi-T180 | 180°C | The increased working temperature up to 180°C |
| High-operating-temperature block | -50°C to 180°C, 200°C peak, film RTI 220°C | The block printed under high operating temperature |
| Electrical breakdown | Greater than 8 kV | The electrical-performance line on the flyer |
The high-operating-temperature block is its own set of figures
As of November 7, 2026, the flyer prints an operating temperature of -50°C to 180°C, up to 200°C peak, in the block headed high operating temperature. The same block says the insulation film RTI is 220°C according to UL tests. Those three figures sit together. They are not the same sentence as the 105°C, 130°C, and 180°C product names. A request for MHi-T130 copies 130°C from the product name. A request that also needs the operating block copies -50°C to 180°C, the 200°C peak, and the 220°C RTI as that block prints them. Electrical breakdown greater than 8 kV is the line under electrical performances. The flyer also lists REACH, RoHS, UL 94 V-0, and EN 45545-2 HL3 for R1 and R7.
The applications line on the flyer, as of November 7, 2026, names motor drives, rail, photovoltaic, wind, aeronautics, UPS, and oil and gas. That list does not assign one industry to one of the three product names. The February 2020 SiC inverter booklet, opened the same day, says the MHi-Txx laminated busbar series is ready for 105°C, 130°C, and 180°C, and a callout says now up to 180°C. That booklet also draws film names beside a temperature pyramid. The boundaries on that drawing are not a table with one film per temperature, so this page does not assign Kapton, Nomex, or Mylar to a pyramid band. Storm's film table is the page that prints a continuous-use temperature next to each film name.
A film's continuous-use cell is not this working temperature
Storm's film table, opened November 7, 2026 and used on the insulation film page, lists Kapton at 400°C continuous use and Nomex at 220°C. The MHi-T flyer describes its insulation as polyaramid, which is the Nomex family, and its highest named working temperature for the busbar is 180°C, with a 200°C peak and a 220°C film RTI in the operating block. Those are different sentences from different documents. A drawing that needs the film row copies Storm's continuous-use cell. A drawing that needs the Mersen busbar series copies MHi-T105, MHi-T130, or MHi-T180. The design guide says the MHi-T construction uses polyaramid dielectric and high-temperature adhesive. It does not print a film thickness for that series.
What to copy onto the busbar line
- Series: traditional laminated, MHi-T105, MHi-T130, or MHi-T180, from the flyer opened November 7, 2026.
- Working temperature: 105°C for the traditional limit, or 105°C, 130°C, or 180°C for the named MHi-T product.
- Operating block, when the request uses it: -50°C to 180°C, 200°C peak, insulation-film RTI 220°C.
- Electrical breakdown: greater than 8 kV, from the flyer.
- Construction: polyaramid dielectric and high-temperature adhesive.
- Listings the flyer names: UL 94 V-0, EN 45545-2 HL3 for R1 and R7, REACH, and RoHS.
Questions the MHi-T pages answer
Is MHi-T105 the traditional 105°C bar?
The flyer limits traditional laminated bus bars to 105°C and also lists MHi-T105 at 105°C, as of November 7, 2026. The increased temperatures it names are up to 130°C and 180°C. The order names MHi-T105 when that product name is the one required.
Does the 200°C peak replace the 180°C name?
MHi-T180 is the 180°C product name, as of November 7, 2026. The high-operating-temperature block prints -50°C to 180°C and up to a 200°C peak, plus a 220°C film RTI. Copy the block when the request asks for that block, and copy MHi-T180 when the request asks for the product name.
What breakdown does the flyer print?
Electrical breakdown is greater than 8 kV, as of November 7, 2026. The flyer does not print a current or a bar size next to MHi-T105, MHi-T130, or MHi-T180.
Sources
The 105°C traditional limit, the MHi-T105, MHi-T130, and MHi-T180 names, the operating block, and the breakdown figure are from Mersen flyer FL-MHI-T-001. The design guide repeats the lineup temperatures. The SiC booklet repeats 105°C, 130°C, and 180°C for the MHi-Txx series. All three were opened November 7, 2026.