Use Y-code part 1146462 when one 8-position cable has to carry power and 100 Mbps. As of October 21, 2026, that page lists 6 A on the power conductors and 0.5 A on the data conductors, at 48 V AC and 50 V DC, on a 1 m PUR hybrid. Use M-code part 1414945 when the cable is power only: 8 A at a nominal 690 V AC, 6 x 1.5 mm², with no Ethernet rate on that page. The keys are different. Part 1146462 is marked discontinued, with no stock replenishment after September 30, 2026.
What 1146462 publishes for power and data
Part 1146462, as of October 21, 2026, is NBC-M12MRY/1,0-94H. The headline calls it a hybrid cable, Ethernet hybrid CAT5 (100 Mbps), 8-position, PUR halogen-free, black RAL 9005, shielded with Advanced Shielding Technology, angled M12 plug, coding Y, IP65/IP67, free cable end, length 1 m, Power with Ethernet (PWE). Nominal voltage is 48 V AC for power and data, and 50 V DC for power and data. Nominal current is 6 A power and 0.5 A data. Transmission speed is 100 Mbps. The interface line says Ethernet hybrid CAT5 (IEC 11801), 100 Mbps. The connector type line also names EtherCAT CAT5 (IEC 11801), 100 Mbps, and PROFINET CAT5 (IEC 11801).
Conductor structure is 1x4x AWG 26 plus 1x4x AWG 18. Data cross section is 4 x 0.15 mm². Power cross section is 4 x 0.85 mm². AWG signal line is 26. AWG power supply is 18. Outside diameter is 8.80 mm plus or minus 0.2 mm. Wire colors are white/orange, orange, white/green, green, white, blue, brown, and black. Loop resistance is at most 280.00 ohms per kilometer on data and at most 45.00 ohms per kilometer on power. Cable nominal voltage is at most 125 V peak, and the page says that voltage is not for high-power applications. Wave impedance is 100 ohms plus or minus 5 ohms at 100 MHz.
The connector standard is IEC 61076-2-113. Seal material is FKM. Tightening torque is 0.4 Nm. Insertion and withdrawal cycles are at least 100. Contact material is CuZn with a Ni/Au surface. Pollution degree is 3. Overvoltage category is II. Flammability rating according to UL 94 is V0. Connector insulation resistance is at least 100 megaohms. Plug ambient temperature is -25°C to 85°C. Degree of protection is IP65 and IP67. Minimum order quantity is 1 pc. Country of origin is PL. GTIN is 4063151137533. Weight including packing is 149.166 g. Weight excluding packing is 22.22 g. Both weights were on the page on October 21, 2026.
The 1 m part is discontinued
The page says discontinued, no stock replenishment after September 30, 2026. That line was still on the item on October 21, 2026, together with the ratings above. The same page lists similar hybrid cables NBC-M12MRY/3,0-94H, item 1146466, and NBC-M12MRY/5,0-94H, item 1146469, and those cards say available to sell. This note did not open 1146466 or 1146469, so their voltage and current are not copied here. A 3 m or 5 m hybrid request starts by opening those items. A 1 m request has to reckon with the replenishment line on 1146462.
When the port is M-code power instead
Part 1414945, opened the same day, is a 6-position unshielded M-code power cable, 10 m, PUR, nominal 690 V AC and 8 A, 6 x 1.5 mm², 16 AWG. It does not list a transmission speed. Y-code 1146462 is shielded, 8-position, 6 A power and 0.5 A data, 48 V AC and 50 V DC, 100 Mbps. Match the key on the device. The M-code length and jacket choice covers 1414945, the configurable item 1276554, and the retired PVC item 1414947. D-code and X-code Ethernet are data keys to an RJ45, not this hybrid shell. T, L, S, and K power are the other power keys.
| Item | Key and job | Nominal voltage | Nominal current | Data rate |
|---|---|---|---|---|
| 1146462 | Y-code, power and Ethernet, 1 m | 48 V AC and 50 V DC | 6 A power, 0.5 A data | 100 Mbps |
| 1414945 | M-code, power only, 10 m PUR | 690 V AC | 8 A | None printed |
Cable temperature, shield, and the approvals rows
Cable fixed installation temperature is -40°C to 80°C. Flexible installation is -30°C to 70°C. Installation and drag-chain use are both -20°C to 60°C. Fixed bend radius is 4 x D. Flexible bend radius is 8 x D. The dynamic bending line lists a maximum of 2000000 cycles, bending radius 15 x D, traversing path 4.5 m, traversing rate 3 m/s, acceleration 3 m/s², and ambient -20°C to 60°C. UL AWM Style is 20233 (80°C/300 V). That style line is on the cable block. Halogen-free is according to IEC 60754-1. Flame resistance lists UL 1581, Section 1060 and UL 2556, Section 9.3 (FT1), and IEC 60332-1-2. Oil resistance lists IEC 60811-404 and DIN EN 50363-10-2. Cable insulation resistance is at least 5 GΩ*km. Optical shield covering is 85 percent.
The approvals table, as of October 21, 2026, prints keine in the name cell. One row under that name is 56.5 V and 0.175 A. Further approval-specification rows label Power at 48 V and 6 A, and Data at 50 V and 0.5 A. The nominal lines at the top of the page are 48 V AC, 50 V DC, 6 A power, and 0.5 A data. Keep the 56.5 V and 0.175 A row with those nominal lines.
What to record before ordering a hybrid cable
- Device port and the letter Y.
- Item number. For the 1 m angled plug opened here, 1146462, plus the discontinued line dated September 30, 2026.
- Power current 6 A and data current 0.5 A, and whether the circuit is 48 V AC or 50 V DC.
- 100 Mbps, and whether the device document says EtherCAT or PROFINET.
- Length. The opened item is 1 m. The 3 m and 5 m cards on that page are 1146466 and 1146469.
- Shield, PUR jacket, and free end.
Questions about the hybrid rating
Can the M-code power cable carry the 100 Mbps pair?
Part 1414945 is unshielded power, 6 x 1.5 mm², and that page prints no transmission speed. Part 1146462 is the shielded 8-position hybrid at 100 Mbps. The hybrid port takes 1146462. The power-only M-code port takes 1414945.
Can 1146462 still be named on a new build?
The page still shows the ratings and says there is no stock replenishment after September 30, 2026. A drawing that names 1146462 should also name that status and the date the page was read. The 3 m and 5 m similar items were marked available to sell on the 1146462 page. Open those items before treating them as the replacement.
Which cable voltage is the limit, 50 V DC or 125 V peak?
Connector nominal voltage is 48 V AC and 50 V DC. Cable nominal voltage is at most 125 V peak, and the page says that figure is not for high-power applications. The approvals row of 56.5 V and 0.175 A is a third line. Use the line the equipment requires, and keep the other two on the note.